DIAGnostic:INTerrupt[:LINE]
DIAGnostic:INTerrupt[:LINE] <card_number>, <line_number> sets Multiplexer
interrupt line. The card_number specifies which Agilent E8462A in a
multiple-module switchbox, is being referred to. The line_number can be 1 through
7 corresponding to VXI backplane interrupt line 1-7.
Parameter
Comments • Setting <line_number> = 0 will disable the Multiplexer’s interrupt.
• Only one value (1 through 7) can be set at one time.
• The default value of <line_number> is 1 (lowest interrupt line).
Example Setting the Multiplexer’s interrupt line equal to interrupt line 6.
DIAG:INT:LINE 1, 6
S e t t h e i n t e r r u p t l i n e e q u a l t o l i n e 6 .
DIAGnostic:INTerrupt[:LINE]?
DIAGnostic:INTerrupt[:LINE]? <card_number> queries the module’s VXI
backplane interrupt line and the return value is one of 1, 2, 3, 4, 5, 6, 7 which
corresponding to the module’s interrupt line 1-7. The return value being 0 indicates
that the Multiplexer is interrupt disabled. The card_number specifies which Agilent
E8462A in a multiple-module switchbox, is being referred to.
Parameter
Comments • Return value of “0” indicates that the Multiplexer’s interrupt is disabled.
Return values of 1-7 correspond to VXI backplane interrupt lines 1 through 7.
• When power-on or reset the module, the default interrupt line is 1.
Example Query the Multiplexer’s interrupt line.
DIAG:INT:LINE 1, 6
Set the interrupt line equal to 6.
DIAG:INT:LINE?
Query the Multiplexer’s interrupt line.
Name Type Range of Values Default Value
<card_number>
<line_number>
numeric
numeric
1 - 99
0 - 7
1
1
Name Type Range of Values Default Value
<card_number> numeric 1 - 99 1