[SENSe:] FUNCtion[:<function>]
FUNCtion?
RESistance:APERture <time> | MIN | MAX
RESistance:APERture? [MIN | MAX]
RESistance:NPLC <number> | MIN | MAX
RESistance:NPLC? [MIN | MAX]
RESistance:OCOMpensated OFF | 0 | ON | 1
RESistance:OCOMpensated?
RESistance:RANGe <range> | MIN | MAX
RESistance:RANGe? [MIN | MAX]
RESistance:RANGe:AUTO OFF | 0 | ON | 1
RESistance:RANGe:AUTO?
RESistance:RESolution <resolution> | MIN | MAX
RESistance:RESolution? [MIN | MAX]
VOLTage:AC:RANGe <range> | MIN | MAX
VOLTage:AC:RANGe? [MIN | MAX]
VOLTage:APERture <time> | MIN | MAX
VOLTage:APERture? [MIN | MAX]
VOLTage[:DC]:RANGe <range> | MIN | MAX
VOLTage[:DC]:RANGe? [MIN | MAX]
VOLTage:NPLC <number> | MIN | MAX
VOLTage:NPLC? [MIN | MAX]
VOLTage:RANGe:AUTO OFF | 0 | ON | 1
VOLTage:RANGe:AUTO?
VOLTage:RESolution <resolution>
VOLTage:RESolution? [MIN | MAX]
Select measurement function.
Query measurement function.
Set aperture (integration) time in seconds.
Query aperture (integration) time.
Set integration time in PLCs.
Query integration time.
Enable/disable offset compensation.
Query offset compensation mode.
Select range.
Query range.
Enable/disable autorange function.
Query autorange mode.
Specify resolution.
Query resolution.
Select measurement range.
Query range.
Set aperture (integration) time in seconds.
Query aperture (integration) time.
Select range.
Query range.
Set integration time in PLCs.
Query integration time.
Enable/disable autoranging.
Query autorange mode.
Specify resolution.
Query resolution.
SYSTem :CDEScription? <card_number>
:CTYPe? <card_number>
:ERRor?
Return description of multiplexer in
scanning multimeter.
Return card type of multiplexer in
scanning multimeter.
Return error number/message from error
queue.
TRIGger :COUNt 1-16777215 | MIN | MAX
:COUNt? [MIN | MAX]
:DELay 0-16.777215 | MIN | MAX
:DELay? [MIN | MAX]
:DELay:AUTO OFF | 0 | ON | 1
:DELay:AUTO?
[:IMMediate]
:SOURce BUS | EXT | HOLD | IMM | TTLTrg0-TTLTrg7
:SOURce?
Set number of triggers or scans.
Query trigger count.
Set delay between trigger and start of
measurement.
Query trigger delay.
Enable/disable automatic trigger delay.
Query automatic trigger delay mode.
Trigger immediately.
Specify trigger source.
Query trigger source.
Command Description
Command Title Description
*RST Reset Sets the multimeter and associated multiplexers. Sets FUNC:VOLT:DC, VOLT:RANG 8V,
RES:RANG 16384, RANGE:AUTO ON, VOLT:RES 7.629mV, RES:RES 15.6m, APER
16.7ms|20ms, NPLC 1, RES:COMP OFF, CAL:ZERO:AUTO ON, TRIG:COUN 1,
TRIG:DELAY:AUTO ON, TRIG:SOUR IMM, SAMP:COUN 1, SAMP:SOURIMM,
SAMP:TIM 200s
*TRG Bus Trigger When the multimeter is in the wait-for-trigger state and the trigger source is
TRIGger:SOURce BUS, use the *TRG command to trigger the multimeter.
*TST Self-Test Should return 0. If code 1, 2, 3, or 4 occurs, return the multimeter to Agilent Technologies
for repair.