Setting Up ParBERT Setting Up a System with Expander Frames
38 Agilent 81250 ParBERT Installation Guide, February 2002
Connecting the Synchronization Cables to
Master Frame
The synchronization cables from the expander frames have to get
connected to the first clock module of the master mainframe.
To connect the synchronization cables:
1 Remove the first clock module from the master mainframe, as
described in ”How to Remove a Module” on page 44.
2 Open the clock module, as described in ”How to Open a Module” on
page 47.
3 Plug the synchronization cables from the expander frames onto the
clock module, as shown in Figure 18.
Figure 18 Connectors of the Master Mainframe’s Clock Module
4 Close the clock module and re-insert it in the mainframe. See ”How to
Add a Module” on page 44.
Clock module of master
mainframe
Synchronization cables