Specifications

4
Option configurations
To add options to a product, order the corresponding item number.
Description For N5241A For N5242A For N5244A For N5245A Additional information
Test set
Option 200 2-ports, single source N5241A-200 N5242A-200 N5244A-200 N5245A-200
Option 224 2-ports, add internal N5241A-224 N5242A-224 N5244A-224 N5245A-224 Requires Options 200, one of 219 or
2nd source, combiner H85, and 080
and mechanical switches
Option 400 4-ports, dual source N5241A-400 N5242A-400 N5244A-400 N5245A-400 Option 080 recommended
Option 423 4-ports, add internal combiner N5241A-423 N5242A-423 N5244A-423 N5245A-423 Requires Options 400, one of 419 or
and mechanical switches H85, and 080
Power configuration
Option 219 2-ports, extended power N5241A-219 N5242A-219 N5244A-219 N5245A-219 Requires Option 200
range and bias-tees
Option 419 4-ports, extended power range N5241A-419 N5242A-419 N5244A-419 N5245A-419 Requires Option 400,
and bias-tees Option 080 recommended
Option H85
1
High power configurable N5241AS-H85 N5242AS-H85 N5244AS-H85 N5245A-H85 Requires Option 200 for 2-port,
(for 2- or 4-port) Option 400 for 4-port
Measurement applications
Option 010 Time-domain measurements N5241A-010 N5242A-010 N5244A-010 N5245A-010
Option 028
2
Noise figure measurements N5241A-028 N5242A-028 N5244A-028 N5245A-028 Requires Option 080
using standard receivers
Option 029
2
Fully-corrected noise figure N5241A-029 N5242A-029 N/A N/A Requires one of Options 219, 224
measurements 419, 423, or H85, and Option 080
Option H29
2
Add 26.5 GHz noise receivers N/A N/A N5244AS-H29 N5245AS-H29 Requires Option 423
Option 080 Frequency offset N5241A-080 N5242A-080 N5244A-080 N5245A-080
Option 082
3
Scalar-calibrated converter N5241A-082 N5242A-082 N5244A-082 N5245A-082 Requires Option 080
measurements
Option 083
3
Vector- and scalar-calibrated N5241A-083 N5242A-083 N5244A-083 N5245A-083 Requires Option 080
converter measurements
Option 084 Embedded LO measurements N5241A-084 N5242A-084 N5244A-084 N5245A-084 Requires at least one of Options
028, 029, H29, 082, 083, or 087
Option 086 Gain compression application N5241A-086 N5242A-086 N5244A-086 N5245A-086 Options 219, 419 or H85 recommended
Option 087 Intermodulation distortion N5241A-087 N5242A-087 N5244A-087 N5245A-087 Requires Options 224 or 423
application
Option 460 Integrated true-mode stimulus N5241A-460 N5242A-460 N5244A-460 N5245A-460 Requires Option 400
application
Option 551
4
N-port capabilities N5241A-551 N5242A-551 N5244A-551 N5245A-551
Nonlinear vector network analysis
Option 510 Nonlinear component N5241A-510 N5242A-510 N5244A-510 N5245A-510 Requires Options 419 and 080, or
characterization 400, H85 and 080
Option 514 Nonlinear X-parameters
5
N5241A-514 N5242A-514 N5244A-514 N5245A-514 Requires Options 423 and 510
Option 518 Nonlinear pulse envelope N5241A-518 N5242A-518 N5244A-518 N5245A-518 Requires Options 021 and 025
domain and either one of 510 or 514
Option 520 Arbitrary load-impedance N5241A-520 N5242A-520 N5244A-520 N5245A-520 Requires Option 514
X-parameters
Required NVNA accessories
U9391C 10 MHz to 26.5 GHz or U9391F 10 MHz to 50 GHz comb generator (two required for nonlinear measurements)
Agilent power meter and sensor or USB power sensor
Agilent calibration kit, mechanical or ECal
Agilent signal generator, MXG or PSG used for X-parameter extraction (internal 10 MHz reference output can be used for 10 MHz tone spacing applications)
1. Order special model N524xAS instead of N524xA and add items N524xA-200 and N524xAS-H85 for 2-port, extended power range, high power configuration,
or items N524xA-400 and N524xAS-H85 for 4-port, extended power range, high power configuration. Order N524xA-xxx items for other standard options.
Option H85 modifies the extended power range and bias-tees (Options 219 and 419), and therefore, they cannot be ordered together.
2. For source-corrected measurements, Options 028, 029, and H29 require an ECal module for use as an impedance tuner. For calibration, Options 029 and
H29 also require a 346-series noise source (Agilent 346C recommended), while Option 028 requires a power meter. All options require a power meter for
measuring mixers and converters.
3. Option 082 is a subset of Option 083; therefore, they cannot be ordered together.
4. When configured as a multiport analyzer using Option 551 and a multiport test set, the combiner feature of Option 224 or 423 is temporarily disabled.
When configured as a standalone analyzer, the combiner feature is enabled. When ordering a test set, select an option to specify the appropriate
interconnect jumper cable set between the analyzer and the test set.
5. X-parameters is a trademark of Agilent Technologies
N5241A 10 MHz to 13.5 GHz
N5242A 10 MHz to 26.5 GHz
N5244A 10 MHz to 43.5 GHz
N5245A 10 MHz to 50 GHz
PNA-X Series Network Analyzer