Specifications

36
Q Band
Q11644A standard, WR-22: 33 to 50 GHz.
Includes:
11644-60005 Q-band termination
11644-20004 Q-band short
11644-20001 Q-band shim
11644-60002 Q-band 10 cm straight waveguide
11644-60017 Q-band 5 cm straight waveguide
85133F cable set (set, flexible, 2.4 mm, 53 cm each,
21 inches each)
Q281A adapter (2.4 mm (f) to WR-22 waveguide adapter)
Q281B adapter (2.4 mm (m) to WR-22 waveguide adapter)
U Band
U11644A standard, WR-19: 40 to 60 GHz.
Includes:
11644-60006 U-band termination
11644-20004 U-band short
11644-20002 U-band shim
11644-60003 U-band 10 cm straight waveguide
11644-60018 U-band 5 cm straight waveguide
V Band
V11644A standard, WR-15: 50 to 75 GHz.
Includes:
11644-60025 V-band termination
11644-20015 V-band short
11644-20013 V-band shim
11644-60012 V-band standard section
Verification kits
All Agilent verification kits include:
• precision Z
0
airline or match thru
• mismatched airline or mismatch thru
• fixed attenuators
• traceable measured data and uncertainties
85053B 300 kHz to 26.5 GHz 3.5 mm kit
Includes attenuators, airline and mismatch airline with data on
a 3.5-inch disk for use in confirming accuracy enhanced system
measurement performance, traceable to national standards.
Test procedure is provided in the service manual.
85055A 300 kHz to 18 GHz Type-N kit
Includes attenuators, airline and mismatch airline with data on
a 3.5-inch disk for use in confirming accuracy enhanced system
measurement performance, traceable to national standards.
Test procedure is provided in the service manual.
85057B 45 MHz to 50 GHz 2.4 mm kit
Includes attenuators, airline and mismatch airline with data on
a 3.5-inch disk for use in confirming accuracy enhanced system
measurement performance, traceable to national standards.
Test procedure is provided in the service manual.
85058V 45 MHz to 67 GHz 1.85 mm kit
Includes attenuators, match thru and mismatch thru with data
on a 3.5-inch disk for use in confirming accuracy enhanced
system measurement performance, traceable to national
standards. Test procedure is provided in the service manual.