Specifications
14
PNA Series Network Analyzer
1
E8362C 10 MHz to 20 GHz E8361C 10 MHz to 67 GHz
E8363C 10 MHz to 40 GHz N5250C
2
10 MHz to 110 GHz
E8364C 10 MHz to 50 GHz
Option configurations
To add options to a product, order the corresponding item number.
Description For E8362C For E8363C For E8364C For E8361C For N5250C Additional
system
3
information
Test set
Option 014 • Configurable test set E8362C-014 E8363C-014 E8364C-014 E8361C-014 Included
Power configuration
Option UNL • Extended power range E8362C-UNL E8363C-UNL E8364C-UNL E8361C-UNL Included Only E8361C
and bias-tees requires 014
Option 016 • Add receiver attenuators E8362C-016 E8363C-016 E8364C-016 E8361C-016 E8361C-016 Requires UNL
(only E8361C also
requires 014)
Option H85
7
• High-power configuration E8362CH85 E8363CH85 E8364CH85 Contact Contact Includes 014, 016,
Agilent Agilent UNL*
4
, 080, 081
Measurement applications
Option 010 • Time-domain capability E8362C-010 E8363C-010 E8364C-010 E8361C-010 E8361C-010
Option 080 • Frequency offset E8362C-080 E8363C-080 E8364C-080 E8361C-080 Included Requires 014
(E8361C only, 081
required if UNL is
also purchased)
Option 081 • Reference receiver switch E8362C-081 E8363C-081 E8364C-081
E8361C-081
Included Requires 014, 080
(only E8361C also
requires UNL)
Option 082 • Scalar-calibrated E8362C-082 E8363C-082 E8364C-082 E8361C-082 E8361C-082
5
Requires 014, 080
converter measurements
Option 083 • Vector- and scalar-calibrated E8362C-083 E8363C-083 E8364C-083 E8361C-083 E8361C-083
5
Requires 014, 080,
converter measurements 081(only E8361C
also
requires UNL)
Option 084
6
• Embedded LO measurements E8362C-084 E8363C-084 E8364C-084 E8361C-084 E8361C-084 Requires 082 or 083
Option 550
9
•
4-port measurement application
E8362C-550 E8363C-550 E8364C-550 E8361C-550 N/A Requires 014
Option 551
9
• N-port capabilities E8362C-551 E8363C-551 E8364C-551 E8361C-551 N/A Requires 014
Pulse, antenna, mm-wave
Option H08 • Pulsed-RF measurement E8362C-H08 E8363C-H08 E8364C-H08 E8361C-H08 E8361C-H08
5
Requires 014, 080
capability (Option H11 recommended)
Option H11
• IF access (for antenna, E8362C-H11 E8363C-H11 E8364C-H11 E8361C-H11 Included Requires 014, UNL,
pulsed-RF and mm-wave 080, and 081
measurements)
Accessories
Option 1CM • Rack mount kit for use E8362C-1CM E8363C-1CM E8364C-1CM E8361C-1CM E8361C-1CM
without handles
Option 1CP • Rack mount kit for use E8362C-1CP E8363C-1CP E8364C-1CP E8361C-1CP E8361C-1CP
with handles
N4688A • USB CD R/W drive N4688A N4688A N4688A N4688A N4688A
N4689A • USB Hub N4689A N4689A N4689A N4689A N4689A
Calibration documentation
Option 1A7 • ISO 17025 compliant E8362C-1A7 E8363C-1A7 E8364C-1A7 E8361C-1A7 E8361C-1A7
calibration
Option UK6 • Commercial calibration E8362C-UK6 E8363C-UK6 E8364C-UK6 E8361C-UK6 E8361C-UK6
certificate with test data
Option A6J • ANSI Z540 compliant E8362C-A6J E8363C-A6J E8364C-A6J E8361C-A6J E8361C-A6J
calibration
Calibration software for self-maintainers
Option 897
8
•
Perpetual license of built-in
E8362C-897 E8363C-897 E8364C-897 E8361C-897 E8361C-897
performance test software for Agilent exclusive calibration
Option 898
8
•
Perpetual license of built-in
E8362C-898 E8363C-898 E8364C-898 E8361C-898 E8361C-898
performance test software for standards compliant calibration
1. All models are not available in all countries.
2. For more detailed information regarding the 110 GHz network analyzer system, refer to the Agilent Web site: www.agilent.com/find/pna
and download the N5250C Technical Overview, literature number 5989-7620EN.
3. The N5250C 110 GHz system also includes an N5260A millimeter-wave test set controller, 1.0 mm combiner assembly, interconnect cables,
and installation and productivity assistance.
4. UNL* does not include bias-tees. Only includes source attenuators.
5. Up to 67 GHz.
6. Requires firmware A.07.05 and above, plus 1.1 GHz CPU board.
7. Option H85 is ordered as a separate model, as indicated.
8. Additional hardware required. Please refer to the analyzer’s Service Guide for required service test equipment.
9. Option 550 is a subset of 551; therefore they cannot be ordered together. When ordering a test set, select an option to specify the appropriate
interconnect jumper cable set between the analyzer and the test set.