Specifications
13
1. Functions up to 67 GHz.
2. Option 087 intermodulation distortion measurements provides spectrum-analyzer-
like display for use with IMD measurements.
3. For example, on-wafer, in-fixture, or waveguide applications.
4. A non-insertable device is a device that cannot be inserted in place of a zero-
length through. For example, a device that has the same connectors on both
ports (type and sex) or different types of connectors on each port (for example,
waveguide on one port and coaxial on the another).
5. Time domain gating is not supported.
6. ECal modules do not cover the whole frequency range of the E5061B. Check
whether the frequency range of each ECal module meets your measurement needs.
7. For more information, see page 25.
8. Physical Layer Test System (PLTS) 4.5 only supports E5071C-x4x, x8x.
9. Closed environment, which does not allow access to a Windows desktop operating
system.
10. Open environment, which allows access to a Windows desktop operating system and
enables you to install software and manage data for easy post-measurement analysis.
11. Includes integrated programming language such as Visual Basic for Applications
®
, and
ability of open Windows environments to install programming languages into analyzers.
12. S11 vector and S21 scalar.
13. 85070E Dielectric Probe Kit only.
14. The source and receiver calibrations are not available. For trace normalization, use Data/
Memory math function since the response calibration is not applicable to absolute traces.
Research and development
FieldFox
N9912A N9923A
ENA-L ENA LF ENA PNA-L PNA-X PNA MW
PNA/PNA-X
millimeter
wave
Basic measurements
S-parameters
●
12
● ● ● ● ● ● ● ●
Transmission and reflection with T/R test set
●
12
● ●
Gain-phase test port with 1 Mohm input
●
X-parameters
●
Absolute power
● ● ●
14
● ● ● ● ●
1
Spectrum analyzer function
●
●
2
Non-coaxial devices
3
TRL calibration (on-wafer measurement)
● ● ● ● ●
Waveguide measurements
● ● ● ● ●
Non-insertable devices
4
Adapter-removal calibration using
mechanical calibration
● ● ● ●
SOLR (unknown thru) using
mechanical calibration or ECal
● ● ● ●
Different connector types supported by ECal
● ●
6
● ● ● ● ●
1
Applications
Gain compression
●
Intermodulation and harmonic distortion
●
True mode differential
●
Nonlinear component characterization
●
Nonlinear pulse envelope domain
●
Time-domain mode/gating
●
5
● ● ● ● ● ●
Frequency-offset mode
●
● ● ● ●
TOI and harmonics
● ● ● ● ●
Noise figure measurements
●
Pulsed-RF: wide and narrow pulse width
● ● ● ● ● ●
Frequency conversion application
● ● ● ●
1
Scalar-calibrated converter measurements
● ● ● ● ●
1
Antenna
● ● ● ● ● ● ● ●
Materials measurement
7
●
13
●
13
● ● ● ● ● ● ●
Signal integrity
●
7
● ● ●
Automated gain compression
●
True differential measurements
●
Programming and connectivity
Windows-OS
●
9
●
9
●
9
●
10
●
10
●
10
●
10
●
10
●
10
LAN interface
● ● ● ● ● ● ● ● ●
Internal programming capability
11
● ● ● ● ● ● ●
ADS linkage
● ● ● ● ●
VEE linkage
● ● ● ●
IntuiLink
● ● ● ● ●
LXI compliance
● ● ●
Display touch screen opt
● ● ● ● ● ●
USB for mass storage
● ● ● ● ● ● ● ● ●
Measurement Solutions for Your Application
Research and development