User manual
lpErrorDoc.txt
valid, but old version of the interface FPGA.
808 Digital module unlock error; The output clock is not locked. The clock
output may not be valid. Please make sure all references and clocks
are connected and the module is set up properly.
This error occurs when the output clock modules are not locked.
This can occur when the externally supplied clock is not stable,
the module is not set up properly, or the internal clock is not
locked. If the error persists after fixing all external causes,
then the module may need to be reset by turning it off then on.
This will set up the clock modules properly.
809 Digital module missing clock; Please make sure the external clock is
connected and the clock settings are correct.
This error occurs when the output clock modules are not receiving a
clock. This usually happens when the external or Device clock
source is selected and there is no clock source connected to the
clock input. If the error persists after fixing all external
causes, then the module may need to be reset by turning it off then
on. This will set up the clock modules properly.
810 Enhanced ACPR module overheated; The Enhanced ACPR Module is
overheating and had been turned off as a precautionary measure. Please
contact Product Support for assistance
This error is reported when the Enhanced ACPR Module is
overheating; this could indicate a failure of the cooling fans and
the unit has been turned off as a precautionary measure.
Page 66