User manual
lpErrorDoc.txt
time. This error is reported when the user attempts to activate one
type of modulation while the other is activated. The modulation
type that was most recently requested will be turned on and the
modulation that was on at the time will be turned off.
640 WB I/Q Settings conflict; WB I/Q and AM WB cannot be on at the same
time: Mux I/Q path and WB I/Q path cannot be on simultaneously
The modulation types I/Q and AM WB cannot be used at the same time.
This error is reported when the user attempts to activate one type
of modulation while the other is activated. The modulation type
that was most recently requested will be turned on and the
modulation that was on at the time will be turned off.
641 File header error; Could not perform header operation on '{name}'
There was a problem performing a header operation on the given
file.
642 Security error; Security level cannot be decreased since instrument is
already in secure mode.
This error occurs when trying to change the security level to a
less secure one and instrument is already in secure mode. The level
in secure mode can only be increased.
645 License specification error; {name}
The file may be corrupt or the firmware may need to be upgraded to
understand the license specification.
648 Waveform Optimized For Different Platform; File {name} is currently
optimized for a different platform. It can be played on this platform,
but may not have the same performance characteristics as it was
designed to have.
File {name} is currently optimized for a different platform. It can be
played on this platform, but may not have the same performance
characteristics as it was designed to have. The burst or alc marker
time alignment could be off or channel optimization (compensation
for the 2,1 Mhz baseband filter on an E4438C for instance) could be
completely inappropriate and actually make the performance worse
than if there was no correction at all.
700 State Save Recall Error; Attempt to delete a non-saved state register.
Delete register ignored.
States that have not been saved cannot be deleted.
700 State Save Recall Error; Cannot recall the User Preset State.
The instrument could not recall the User Preset State, possibly
because it was deleted. Save a new User Preset State.
700 State Save Recall Error; Could not save last state file. Setting to
Power On Preset.
The instrument could not save the last state file, so the power-on
behavior has been set to Power On Preset.
700 State Save Recall Error; Failed to recall the instrument state. {name}
The instrument could not recall an instrument state. Previous error
Page 62