begin on an even sample pair boundary.
630 Arb Sequence Error; Unable to reset sequence on baseband board after
change in file. WFM{value}:{name}
A change was made to a waveform file being referenced by the
sequencer that has made the current sequence invalid. It is likely
that the file contains too few samples. Correct the file size or
the lengths and offsets in single waveform sequences and reenable
the personality. {value} is the number of the baseband board on which
the error occurred. {name} is the name of the file that caused the
problem.
631 Output power unleveled; The ALC is unleveled.
The ALC is unleveled.
632 Power search failed. Power Unleveled.
While executing power search, the level meter closed loop reference
value failed to settle. This event indicates that the power is in
an unstable condition. The power will be set to the last properly
leveled power.
633 Power search failed. Reference reading unsettled.
While executing power search, the level meter closed loop reference
value failed to settle. This event indicates that the power is in
an unstable condition. The power will be set to the last properly
leveled power.
634 Power search failed. ALC open loop unsettled.
While executing power search, the level meter open loop voltage
failed to settle. This event indicates that the power is in an
unstable condition. The power will be set to the last properly
leveled power.
635 Power search failed. ALC abus voltage unsettled.
While executing power search, the level meter ALC voltage failed to
settle. This event indicates that the power is in an unstable
condition. The power will be set to the last properly leveled
power.
636 Power search failed. DAC value exceeded range.
While executing power search, the value requested for the offset
compensation DAC was beyond its available range. This event
indicates a low power level that cannot be compensated with the
hardware. The power will be set to the last properly leveled power.
637 Power search failed. Excessive iterations.
While executing power search, the number of iterations in the power
search algorithm exceeded the allowable limit. This event indicates
an unstable power level. The power will be set to the last properly
leveled power.
640 WB I/Q Settings conflict; I/Q and WB I/Q cannot be on at the same time:
Mux I/Q path and WB I/Q path cannot be on simultaneously
The modulation types I/Q and WB I/Q cannot be used at the same