-221 Settings conflict; Invalid Channel code. Channel code has been changed
to the highest Channel code for this symbol rate
An attempt was made to input a channelization code beyond the
limitations imposed by the symbol rate. The channelization code is
reset to the highest allowable code for the present symbol rate
setting.
-221 Settings conflict; Invalid Channelization code setting. Change
Channelization code setting of physical channels to be orthogonal.
OVSF codes require that physical channel code settings be
orthogonal.
-221 Settings conflict; Invalid power configuration of Transmit Power
Control.
Initial Power and Minimum Power should be multiple value of power
step.
Initial Power should be larger than Minimum Power.
-221 Settings conflict; I/Q and AM WB cannot be on at the same time.
The modulation types I/Q and AM WB cannot be used at the same time.
This error is reported when the user attempts to activate one type
of modulation while the other is activated. The modulation type
that was most recently requested will be turned on and the
modulation that was on at the time will be turned off.
-221 Settings conflict; I/Q and Optimize Noise cannot be on at the same
time. {name}
The Optimize Noise below 500 MHz and I/Q modulation cannot be used
at the same time. This error is reported when the user attempts to
activate one feature while the other one in conflict is activated.
If Optimize Noise below 500 MHz is turned on then the I/Q feature
will be turned off. If I/Q is turned on then Optimize Noise below
500 MHz will be turned off.
-221 Settings conflict; I/Q and Ramp Sweep cannot be on at the same time.
{name}
The Ramp Sweep and I/Q modulation cannot be used at the same time.
This error is reported when the user attempts to activate one
feature while the other one in conflict is activated. If Ramp Sweep
is turned on then the I/Q feature will be turned off. If I/Q is
turned on then Ramp Sweep will be changed to Step Sweep.
-221 Settings conflict; I/Q delay adjustment limits depend on the rate of
the active format. The delay has been limited to the current upper or
lower bound as appropriate.
I/Q delay adjustment limits depend on the rate of the active
format. The delay has been limited to the current upper or lower
bound as appropriate.
-221 Settings conflict; I/Q must be turned on before turning on Constant
Phase.
Constant Phase cannot work with out an I/Q signal to the modulator,
so it does not make sense to turn Constant Phase on without I/Q on.