User manual

lpErrorDoc.txt
-221 Settings conflict; The frequency spacing has been limited by the
number of carriers.
The frequency spacing and the number of carriers must be such that
the bandwidth limitation of the baseband generator is not exceeded.
-221 Settings conflict; The frequency spacing has been limited by the
number of tones.
The frequency spacing and the number of tones must be such that the
80 MHz of bandwidth is not exceeded. If FS_MAX is the maximum
frequency spacing in MHz and N is the number of tones, then {FS_MAX
<= (80) / (N - 1)}.
-221 Settings conflict; The frequency spacing has been limited by the tone
alignment.
The frequency spacing and alignment must be such that the 80 MHz of
bandwidth is not exceeded and that no tone is more than 40 MHz from
the carrier.
-221 Settings conflict; FSK frequency deviation has been limited by the
sample rate.
The Arb Sample Rate must be at least 16 times the Digital Mod FSK
frequency deviation. If this cannot be achieved without exceeding
the maximum sample rate for the current settings, the FSK frequency
deviation will be limited.
-221 Settings conflict; FSK frequency deviation has been limited by the
symbol rate.
The maximum FSK frequency deviation depends on the symbol rate.
-221 Settings conflict; GSM BERT requires multiframe PN Sequence in
Timeslot E field.
An unsupported data type was encountered. The measurement timeslot
requires a multiframe PN sequence in the E field.
-221 Settings conflict; GSM BERT requires Normal as Timeslot Type.
An unsupported timeslot type was encountered. The measurement
timeslot must be designated Normal.
-221 Settings conflict; If amplitude reference state is on, power units
must be dB. If amplitude reference state is off, allowable power units
are dBm, dBuV, dBuVemf, V, and Vemf.
An attempt was made to change the units used when reporting the
amplitude value through SCPI or displaying it on the front panel.
The units specified conflict with the amplitude reference state. If
amplitude reference state is on, power units must be dB. If
amplitude reference state is off, allowable power units are dBm,
dBuV, dBuVemf, V, and Vemf.
-221 Settings conflict; Illegal setting of DCH state. Transport
channels(DCHs) must be turned on sequentially.
Transport channels must be turned on sequentially. For example,
channels 1,2 and 3 must be turned on before channels 4 through 6
can be activated.
Page 28