User manual
lpErrorDoc.txt
This error is generated if the module is not connected when digital
data is turned on.
-221 Settings conflict; The Digital Data state could not be turned on
because there is no Format turned on. Please turn on a format before
turning on the digital module.
When turning the digital module on, a check is made to see if a
format is turned on. This error is generated when no format is
found.
-221 Settings conflict; The Digital Data state was forced off because the
connection to the digital module was lost. You must reconnect the
module to turn Digital Data back on.
When the digital module is disconnected while the state is on, the
state will be forced off. This error is reported to notify the user
that the state was forced off.
-221 Settings conflict; The Digital Data state was forced off because there
are no longer any formats turned on or the digital module was set up
in input mode and the RT Custom format was turned off.
All formats were turned off, so the digital module has to be turned
off as well. In input mode, RT custom must be on, so if it is
turned off the digital module will be turned off as well.
-221 Settings conflict; Discontinuous and Continuous setting conflict. All
selected Discontinuous timeslots are now set to Continuous.
Indicates that while in TETRA mode an attempt has been made to
simultaneously assign discontinuous and continuous protocols to the
timeslots. Discontinuous and continuous protocols cannot coexist in
TETRA mode. If a continuous protocol is selected for any timeslot,
all timeslots' protocols are changed to continuous protocols.
-221 Settings conflict; Doppler shift has been reduced to reflect the new
frequency.
The requested frequency is incompatible with the current value of
the Doppler shift. The Doppler shift has been set to the maximum
value compatible with the new frequency.
-221 Settings conflict; Downlink and Uplink setting conflict. All selected
Downlink timeslots are now set to Uplink.
With uplink selected for one or more timeslots, a downlink timeslot
was selected. For NADC and PDC digital modulation for bursted data,
all traffic channels must be either uplink or downlink. To continue
data transmission, all downlink timeslots have been changed to.
Uplink.
-221 Settings conflict; DPDCH Slot Format #6 does not allow CM by SF/2.
DPDCH Slot Format #6 does not allow CM by SF/2.
-221 Settings conflict; E-TFCI Trigger delay(ETTDelay) value is too large.
E-TFCI Trigger delay(ETTDelay) value should be 0 to 61184 when TTI
is 2msec.
-221 Settings conflict; E-TFCI value is too large.
Page 25