Error Messages Agilent Technologies E8257D/67D PSG Signal Generators This guide applies to the following signal generator models: E8257D PSG Analog Signal Generator E8267D PSG Vector Signal Generator Due to our continuing efforts to improve our products through firmware and hardware revisions, signal generator design and operation may vary from descriptions in this guide. We recommend that you use the latest revision of this guide to ensure you have up-to-date product information.
Notice The material contained in this document is provided “as is”, and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied with regard to this manual and to any of the Agilent products to which it pertains, including but not limited to the implied warranties of merchantability and fitness for a particular purpose.
Error Messages Introduction Introduction If an error condition occurs in the signal generator, it is reported to both the front panel display error queue and the SCPI (remote interface) error queue. These two queues are viewed and managed separately. NOTE When there is an unviewed message in the front panel error queue, the ERR annunciator appears on the signal generator’s display.
Error Messages Error Message Format Error Message Format When accessing error messages through the front panel display error queue, the error numbers, messages and descriptions are displayed on an enumerated (“1 of N”) basis. When accessing error messages using the SCPI (remote interface) error queue, the error numbers and the portions of the error query response are displayed on the host terminal.
Error Messages Error Message Types Error Message Types Events do not generate more than one type of error. For example, an event that generates a query error will not generate a device-specific, execution, or command error. Query Errors (–499 to –400) indicate that the instrument’s output queue control has detected a problem with the message exchange protocol described in IEEE 488.2, Chapter 6. Errors in this class set the query error bit (bit 2) in the event status register (IEEE 488.2, section 11.5.1).
-440 Query UNTERMINATED after indefinite response A query was received in the same program message in which a query requesting an indefinite response was executed (see IEEE 488.2, 6.3.7.5). -430 Query DEADLOCKED A SCPI output queue has filled, preventing further SCPI command execution, and there is no more room left in the corresponding SCPI input queue to accept a query to read from the output queue. The system automatically discards output to correct the deadlock.
lpErrorDoc.txt -321 Out of memory; ARB is not functional. There is insufficient memory for the ARB to generate the requested waveform. -321 Out of memory; BBG 3GPP cannot function properly. 3GPP cannot function properly due to dynamic memory allocation failure. -321 Out of memory; Burst shape subsystem unable to operate. Operations on a Burst Shape could not be completed because of insufficient memory. -321 Out of memory; Cannot convert binary file to bit file.
lpErrorDoc.txt A file system operation has failed due to a lack of memory in the system. Reduce memory usage and try again. -321 Out of memory; FIR subsystem unable to operate. There is insufficient working memory available. Report this error to Agilent Technologies. -321 Out of memory; Graph subsystem cannot function. There is insufficient working memory available. Report this error to Agilent Technologies. -321 Out of memory; High Amplitude is less than Low Amplitude.
lpErrorDoc.txt There is not enough memory to read the specified data file. Try a smaller file. Reduce the size of any list/sweep, and preset the source to clear up any inconsistencies. If the problem persists report this error to Agilent Technologies. -321 Out of memory; Not enough Waveform Memory on BBG{value} There is not enough memory left on the baseband board to generate the required baseband file. Remove any file that might have been previously downloaded and is not required anymore (e.g. ARB files).
lpErrorDoc.txt fragmentation). Report this error to Agilent Technologies. The instrument is still functional. -321 Out of memory; Unable to display timeslot window. The instrument was unable to create part of the graphical user interface due to an inability to allocate memory (possibly due to fragmentation). Report this error to Agilent Technologies. The instrument is still functional. -321 Out of memory; User Flatness subsystem out of memory. There is insufficient working memory available.
lpErrorDoc.txt Cannot restore specified cal from backup because of a file error. -313 Calibration memory lost; Cannot store cal to backup: {name}err={value} Cannot store specified cal to backup because of a file error. -313 Calibration memory lost; Cannot store cal: {name}err={value} Cannot store specified cal because of a file error. -313 Calibration memory lost; Error occurred while trying to load data from previous internal IQ calibration.
lpErrorDoc.txt valid state. -310 System error; Critical digital module error. Report this error to Agilent Technologies. This error cannot be generated under normal operating conditions and should be reported to Agilent Technologies. -310 System error; Error backing up system files. Error encountered while writing system files to backup storage. -310 System error; Error creating directory: {name} Error creating a directory. The directory is shown in error message.
lpErrorDoc.txt The command issued expected a given personality to be loaded on the given board. Report this error to Agilent Technologies. -310 System error; Invalid object. {name} Internal error. File system operation encountered invalid object. -310 System error; Line:{value} file: {name} stack: {name} An internal error occurred at the specified location within the specified file. -310 System error; Media raw. {name} The flash storage media was never formatted or is corrupted.
lpErrorDoc.txt File system volumes were verified. Informational warning. Powering down system (turning the power off) during file system write operation may leave the file system in inconsistent state. On subsequent reboot the volume was verified and errors repaired. -310 System error; Transmit pace not supported Command is not supported for RS232 communication. -310 System error; Unknown file system error. {name} Internal error. -310 System error; Volume already exists: {name} Internal error.
lpErrorDoc.txt The calibration will take an initial coarse YO pretune calibration that consists of a gain and offset term, and refine that to include a cubic term that is applied above 7 GHz to linearize the tuning. -310 System error; {name} An compatibility language specific system error occurred. The string contains information about the error. -310 System error; The {name} subsystem was not found. The requested operation could not be completed. The subsystem named in the error was not found.
lpErrorDoc.txt -271 Macro syntax error A syntactically legal macro program data sequence, written in accordance with IEEE 488.2, 10.7.2, could not be executed due to a syntax error within the macro definition (see IEEE 488.2, 10.7.6.3). -270 Macro error A macro-related execution error occurred. This error message is used when the device cannot detect the more specific errors described for errors -271 through -279.
lpErrorDoc.txt -259 LAN setup error; IP address and default gateway must be on the same subnet. Offending entries are changed. The IP address and default gateway are not on the same network as specified by the subnet mask. Verify that both addresses are on the same subnet and try again. -259 LAN setup error; IP address is inconsistent with subnet mask or IP class rules. Offending entry is changed. The IP address is invalid. Check the entry for syntax and numerical errors and try again.
lpErrorDoc.txt -256 File name not found; {name} The burst shape type has been defaulted. The specified file does not exist, so the burst shape type has been defaulted. -256 File name not found; {name} The filter type has been defaulted. The specified file does not exist, so the filter type has been defaulted. -256 File name not found; {name} The modulation type has been defaulted. The specified file does not exist, so the modulation type has been defaulted.
lpErrorDoc.txt properly. Report this error to Agilent Technologies. -230 Data corrupt or stale; Either the file is not a bit file, or the number of bits specified does not match the number of data bytes in the file. An error has occurred while downloading a user file to the Bit memory catalog. Either the user file is not a bit file, or the number of bits specified in the SCPI command does not match the number of bytes in the file. Ensure that the bit specifier matches the actual number of bits in the file.
lpErrorDoc.txt -224 Illegal parameter value; The OSR must be an even value. RADio:ARB:GENerate:SINE generates a valid sine waveform and the OSR must be an even value to generate a waveform with an even number of samples. -224 Illegal parameter value; This unit does not have an External Baseband Reference input. Instead it has a External Baseband VCO Clock input. This unit does not have an External Baseband Reference input. Instead it has a External Baseband VCO Clock input.
lpErrorDoc.txt Due to hardware limitations, only a certain number of unique data points can be created for the IQ map. IQ rotation is designed to alleviate this problem, but incorrect use can result in undesirable effects. This error indicates that the current IQ rotation is optimal and cannot be changed. -223 Too much data; The number of carriers exceeds the maximum allowed. The maximum number of carriers cannot exceed the maximum that is defined in the technical specifications document.
lpErrorDoc.txt command. -222 Data out of range; A burst rise shape must have at least two points. Two points are needed to specify a rise shape in the MEM:DATA:SHAPe command. -222 Data out of range; A burst shape can only have up to {value} points for the fall shape. The user has specified more than the maximum number of points allowed for the fall shape in the MEM:DATA:SHAPe command. -222 Data out of range; A burst shape can only have up to {value} points for the rise shape.
lpErrorDoc.txt The sweep/list manual point has been reassigned to a smaller number value due to the longest list decreasing in size or being turned off. Its new value is the length of the longest enabled list (frequency or power). -222 Data out of range; Manual point exceeds power list size. Limiting to maximum point. The sweep/list manual point has been reassigned to a smaller number value due to the longest list decreasing in size or being turned off.
lpErrorDoc.txt source frequency; number of points and start/stop values for list mode; start/stop values for internal I/Q calibration; sequence or register values (save/recall); dwell time. -222 Data out of range; {name} clipped to lower limit. An input value is below the minimum value allowed. In some cases the minimum value is affected by other item setting due to coupling. -222 Data out of range; {name} clipped to upper limit. An input value is above the maximum value allowed.
lpErrorDoc.txt turn the mode on. HSPA has been turned off. To output a valid RF signal, at least one channel must be turned on. Since all channels are off, HSPA mode has been turned off to avoid undefined behavior. -221 Settings conflict; At least one of the channels must be on in order to turn the mode on. WCDMA has been turned off. To output a valid RF signal, at least one channel must be turned on. Since all channels are off, WCDMA mode has been turned off to avoid undefined behavior.
lpErrorDoc.txt / NumberOfBlks. But block size does not match the BlockSetSize exactly. Try another value. Block size has been adjusted to match BlockSetSize / NumberOfBlks. But block size is not match to the value exactly, please try another value. -221 Settings conflict; Block size has been adjusted to match BlockSetSize / NumberOfBlocks. Block size has been adjusted to match BlockSetSize / NumberOfBlocks. -221 Settings conflict; Block size of DCH{value} must match to BlockSetSize / NumberOfBlks.
lpErrorDoc.txt -221 Settings conflict; Cannot turn AWGN on, option 403 is required for any AWGN functionality Option 403 (AWGN) is required to enable the AWGN portion of option 400 (WCDMA). -221 Settings conflict; cannot update Baseband generator with Even Second Delay. There is an error with the CDMA2000 or 1xEV-DV hardware. Try turning the CDMA2000 or 1xEV-DV mode off and on again to reset the baseband generator card. If the problem persists, report this error to Agilent Technologies.
lpErrorDoc.txt The clipping function is not available for the CDMA2000 or 1xEV-DV reverse link radio configurations 1 and 2. The value is automatically reset to 100% (no clipping). -221 Settings conflict; Clock Source Synchronized is only allowed when Logic Type is LVDS and Data Direction is Input. Clock Source set to Internal. This error is reported when the Clock Source is set to Synchronized and then the Logic Type is changed from LVDS or the Data Direction is set to Output.
lpErrorDoc.txt format is off: {name}. This error is reported when a file header command is tried when the format is not on. File Headers can only be modified while the format the file is associated with is turned on. {name} is a string describing the Format. -221 Settings conflict; The current data rate is not valid for this radio configuration. Data rate changed to the default rate. The new radio configuration does not support the current data rate.
lpErrorDoc.txt This error is generated if the module is not connected when digital data is turned on. -221 Settings conflict; The Digital Data state could not be turned on because there is no Format turned on. Please turn on a format before turning on the digital module. When turning the digital module on, a check is made to see if a format is turned on. This error is generated when no format is found.
lpErrorDoc.txt E-TFCI value should be 0 to 125 when E-TFCI table is 1 and TTI is 2msec. E-TFCI value shoudl be 0 to 120 when E-TFCI table is 1 and TTI is 10msec. -221 Settings conflict; EDGE BERT requires multiframe PN Sequence in Timeslot E field. An unsupported data type was encountered. The measurement timeslot requires a multiframe PN sequence in the E field. -221 Settings conflict; EDGE BERT requires Normal as Timeslot Type. An unsupported timeslot type was encountered.
lpErrorDoc.txt match the FM1/PM1 deviation. -221 Settings conflict; FM2/PM2 value set greater than FM1/PM1 value. FM1/PM1 changed to match FM2/PM2 value. FM2/PM2 deviation must be FM1/PM1 deviation. This error is reported when both FM1/PM1 and FM2/PM2 are enabled and an adjustment to either FM2/PM2 deviation causes the FM2 or PM2 deviation to be greater than the FM1 or PM1 deviation.
lpErrorDoc.txt -221 Settings conflict; The frequency spacing has been limited by the number of carriers. The frequency spacing and the number of carriers must be such that the bandwidth limitation of the baseband generator is not exceeded. -221 Settings conflict; The frequency spacing has been limited by the number of tones. The frequency spacing and the number of tones must be such that the 80 MHz of bandwidth is not exceeded.
lpErrorDoc.txt -221 Settings conflict; In fixed position the block size must be either 0 or equal to block set size. The block size has been set to the block set size. In fixed position mode the block size must be equal to either the block set size or 0. -221 Settings conflict; In the F-PDCCH overlaid mode, the relative power of the F-PDCCH1 is different from the F-PDCCH0's. In the F-PDCCH overlaid mode, the relative power of the F-PDCCH1 must be same as the F-PDCCH0's.
lpErrorDoc.txt -221 Settings conflict; Invalid Channel code. Channel code has been changed to the highest Channel code for this symbol rate An attempt was made to input a channelization code beyond the limitations imposed by the symbol rate. The channelization code is reset to the highest allowable code for the present symbol rate setting. -221 Settings conflict; Invalid Channelization code setting. Change Channelization code setting of physical channels to be orthogonal.
lpErrorDoc.txt -221 Settings conflict; IR buffer size is too small. The 3GPP standard defines the transport block set size as 0 to 200000 -221 Settings conflict; The maximum value of the Summing Ratio is dependent on the Modulator Atten value. Summing ratio value has been modified to reflect the decreased IQ Modulator Atten value. The maximum value of the Summing Ratio has a dependency on the Modulator Atten value.
lpErrorDoc.txt GAP2 is a single frame method gap that is greater than 7 slots long. DTX slots per frame should be less than 8. -221 Settings conflict; Nfirst2 >= 8 or Nlast2 <= 6 GAP2 is a double frame method gap; the DTX slots per frame is > 7. DTX slots per frame should be less than 8. -221 Settings conflict; Number of E-DPDCH is too many. E-DPDCH channel conflicts with other channel. Reduce the number of E-DPDCH channel or turn off the conflicting channel.
lpErrorDoc.txt data source is external. Single is not a valid repeat setting for an external data source. -221 Settings conflict; PHS or TETRA scramble cannot be on when the currently selected modulation type has more than 2 bits per symbol. The baseband generator provides modulations with more than 2 bits/symbol. For these modulations, PHS and TETRA scramble are disabled. -221 Settings conflict; Power list and dwell list are of unequal size. Set one list equal to size one or make their sizes equal.
lpErrorDoc.txt -221 Settings conflict; QPCH and FFCH/OCNS cannot be on at the same time. FFCH/OCNS has been turned off. QPCH is generated using both channel 3 and 4. Channel 4 is now used to generate QPCH. Channel 3 can no longer generate FFCH/OCNS. Therefore, FFCH/OCNS must be turned off. -221 Settings conflict; RACH is only defined for Radio Configuration 1 and 2. You must set one of these Radio Configurations before configuring or using this code channel.
lpErrorDoc.txt An attempt was made to setup the R-DCCH while in a radio configuration that does not support this channel. This channel is only available in RC3 and RC4. If the R-DCCH is the desired channel, you must change to the proper radio configuration before continuing. -221 Settings conflict; REACH is only defined for Radio Configuration 3 and 4. You must set one of these Radio Configurations before configuring or using this code channel.
lpErrorDoc.txt channel, you must change to the proper radio configuration before continuing. -221 Settings conflict; RSCH is only defined for Radio Configuration 1 and 2. You must set one of these Radio Configurations before configuring or using this code channel. The command attempted to enter a value or setting for the R-SCH in RC1 or RC2. If this is the correct R-SCH, change to the desired radio configuration and resend the command. If not, select the command for the desired R-SCH.
lpErrorDoc.txt firmware release is not available, then an alternate solution is to load a compatible FPGA image by pressing the Update SSIO Interface FPGA soft key located under the Diagnostics menu. DO NOT INTERRUPT the update once it has started. You must cycle power on the N5102A when the update is completed. The Signal Generator is not compatible with the newer version of the N5102A SSIO FPGA.
lpErrorDoc.txt 15 >= TGSN + TGL2 + TGD TGD parameter is set to Undefined or 0. TGPL1 * 15 >= TGSN + TGL1 TGPL1 is the duration of transmission gap pattern 1. The gap pattern consists of TGSN, TGD, TGL1 and TGL2. The gap pattern can't be generated if the TGPL1 value is too short. TGPL1 should meet the condition as below; TGD parameter is not set to Undefined or 0. TGPL1 * 15 >= TGSN + TGL2 + TGD TGD parameter is set to Undefined or 0.
lpErrorDoc.txt increased. To avoid the error, increase the symbol rate of physical channel or decrease the number of bits of TrCHs. -221 Settings conflict; Unsupported configuration for Pilot Gating. Pilot Gating can only be used for the Pilot alone or in conjunction with REACH or RCCCH. Changing the R-PICH gating from full is only allowed in three channel structures: R-PICH, R-PICH with the R-CCCH or R-PICH with the R-EACH. -221 Settings conflict; Uplink and Downlink setting conflict.
lpErrorDoc.txt is defaulted back to EDGE modulation. -221 Settings conflict; When Skew Mode is enabled, the maximum number of filter symbols allowed is 32. The filter type has been defaulted. *** No documentation *** -221 Settings conflict; When the clock rate setting is below 10 MHz or above 200 MHz, only phase settings of 0 and 180 degrees are valid. The phase was changed to a valid setting. When the frequency is changed the phase is set at 90 or 270 by 90 degrees.
lpErrorDoc.txt The data rate is not contained in the defined data rate table. -220 Parameter error; Spread factor exceeds maximum allowable spread factor The spread factor exceeds the maximum allowable spread factor. The maximum allowable spread factor is currently 256. -220 Parameter error; Spread factor not valid The spread factor should be a power of 2 that is between 4 and 256. -220 Parameter error; {name} The modulation type has been defaulted.
lpErrorDoc.txt An arming signal was received and recognized by the device but was ignored. -211 Trigger ignored A GET, *TRG, or triggering signal was received and recognized by the device, but was ignored because of device timing considerations. For example, the device was not ready to respond. -210 Trigger error A GET,*TRG, or a triggering signal could not be executed due to an error. -202 Settings lost due to rtl A setting associated with a hard local control (see IEEE 488.2, 5.6.
lpErrorDoc.txt or type of parameters. -183 Invalid inside macro definition The program message unit sequence, sent with a *DDT or a *DMC command, is syntactically invalid (see IEEE 488.2, 10.7.6.3). -181 Invalid outside macro definition A macro parameter placeholder ($
lpErrorDoc.txt The specified filename exceeds the maximum length. -151 Invalid string data; Header Description String is too long and was clipped to 32 characters. This error occurs when trying to open a header file, the file does not match any known header format or does not exist. {name} is the filename being accessed. -150 String data error An error was encountered when parsing a string data element. Specific details are not available.
lpErrorDoc.txt 7.7.2.4.1). -123 Exponent too large The magnitude of an exponent was greater than 32000 (see IEEE 488.2, 7.7.2.4.1). -121 Invalid character in number An invalid character for the data type being parsed was encountered. For example, an alpha in a decimal numeric or a “9” in octal data. -120 Numeric data error An error was encountered when parsing a data element that appears to be numeric including non-decimal numeric types. Specific details are not available.
lpErrorDoc.txt -104 Data type error The parser recognized a data element that is not allowed. For example, numeric or string data was expected, but block data was encountered. -103 Invalid separator The parser was expecting a separator and encountered an illegal character. For example, the semicolon was omitted after a program message unit. -102 Syntax error An unrecognized command or data type was encountered. For example, a string was received when the device does not accept strings.
lpErrorDoc.txt In 8340/8757 compatibility mode, the OA query was received but it is not supported for the current active function. -100 Command error; R0: No standby mode allowed. In 8656/57 compatibility mode, R0 was received via GPIB. This command is not supported by the compatibility mode. -100 Command error; Remote active function DN/UP not available. In 8656/57 compatibility mode, either DN or UP was received via GPIB. These commands are not supported by the compatibility mode.
lpErrorDoc.txt 211 Not owner; {name} Permission has been denied to perform an operation on the specified file. 219 Bad file number; {name} Invalid file or device name. 220 Arg out of domain of func; {name} An operation failed within the specified file because of an invalid argument. 221 Access denied; Cannot access protected system directory contents. Certain directories contain system files necessary for proper instrument operation.
lpErrorDoc.txt mode, the user has requested a power setting that is below the ALC range for the attenuator setting. The power has been set to the lower limit. 501 Attenuator hold setting over range; Power set to upper limit. The firmware has changed the power setting to a value other than the requested value due to the fact that, while in attenuator hold mode, the user has requested a power setting that is above the ALC range for the attenuator setting. 508 Frac-N Loop unlocked The synthesizer is unlocked.
lpErrorDoc.txt 517 Calibration failure; Cal aborted by user. While executing the internal I/Q calibration, either a DCAS was sent over the GPIB, or the Abort key on the front panel was pressed. 517 Calibration failure; Cannot interpolate the value %1.9e with index array {name}. Index array vals must be sorted in increasing order. The specified calibration files have not been properly initialized.
lpErrorDoc.txt While executing the internal I/Q calibration, a failure occurred while attempting to access the IQ CAL CONSTS Array. This array is required for proper operation of the internal IQ Calibration. This may be caused by faulty motherboard flash but can also be the result of a configuration failure during a firmware upgrade or motherboard replacement. 517 Calibration failure; IQ Calibration failure. Cannot Access IQ CAL TOLERANCE Array.
lpErrorDoc.txt While executing the internal I/Q calibration, a failure occurred. An internal software error has occurred. A measurement node requested by the firmware does not exist. A firmware patch is required. 517 Calibration failure; IQ Calibration failure. IQ Gain iteration error. {name} While executing the internal I/Q calibration, a failure occurred. The IQ Gain could not be calibrated in a reasonable number of iterations. Please check the IQ Mux hardware.
lpErrorDoc.txt While executing the internal I/Q calibration, a failure occurred. Please check the hardware. 520 Sampler Loop unlocked One of the signal generator's samplers is unlocked or one of the sampler circuits are malfunctioning. The instrument may require service. 521 YO Loop unlocked The YIG oscillator phase lock loop is unlocked. The problem may be due to a bad calibration. If not, then the instrument may require service.
lpErrorDoc.txt One or more OCNS channels must be enabled for channel balancing to occur. 600 RPP has tripped. The reverse power protection circuit has been triggered. Repeated tripping of this circuit can cause damage to the instrument. 601 Power search failed. While executing power search, the level meter circuit failed to return a meaningful value. This event indicates that the power is in a range that the leveling loop cannot properly level. The power will be set to the last properly leveled power.
lpErrorDoc.txt to respond within the appropriate amount of time. If cycling power does not correct the problem, report this error to Agilent Technologies. 606 DSP times out; Opt 300 EDGE BERT capability({value}). The digital signal processor (DSP) on the bit error rate tester board failed to respond while Option 300 is operating. Report this error to Agilent Technologies. 606 DSP times out; Opt 300 GSM BERT capability({value}).
lpErrorDoc.txt During the system configuration scan of parallel bus boards, a board with a bad configuration header was detected. Report this error to Agilent Technologies. 617 Configuration Error; Bad board header in serial slot: {value} During the system configuration scan of serial bus boards, a board with a bad configuration header was detected. Report this error to Agilent Technologies. 617 Configuration Error; Baseband generator control could not be created.
lpErrorDoc.txt file conflict or a hardware configuration error. Report this error to Agilent Technologies. 617 Configuration Error; Unexpected BBG{value} Firmware version The BBG firmware code does not match the main firmware. Please load the matching version, or contact Agilent sales and service for assistance. {value} is the BBG board number. 617 Configuration Error; Update of license file failed. Perhaps too many files or flash is full? Happens when user enters/updates license keys.
lpErrorDoc.txt errors below 3.2 GHz. The lowband coupler detector has failed. Report this error to Agilent Technologies. 625 Internal pulse generator unlocked *** No documentation *** 626 Internal modulation source unlocked *** No documentation *** 627 Licensing error; A new challenge value must be generated using 'DIAGnostic:INFO:WLICense:CHALlenge?' Most waveform license SCPI commands require an authentication code which involves a challenge value.
lpErrorDoc.txt provide a challenge value; this value cannot be zero. 627 Licensing error; The waveform file already has or does not require a 5-Pack license. User attempted to add a waveform to a 5-Pack and the waveform already has or does not require a 5-Pack license. 628 Baseband Generator DAC over range; BBG{value}. Reduce the waveform amplitude or reduce the runtime scaling. The output signal will be invalid when this error occurs. Reduce the waveform amplitude or reduce the runtime scaling.
lpErrorDoc.txt First {name} is file name, second is file revision and third is supported revision. 629 File format invalid; Sequence contains an invalid single waveform sequence. This is reported when an invalid single waveform sequence is found in a sequence file. 629 File format invalid; Sequence contains an invalid waveform. This is reported when an invalid waveform is found in a sequence file. 629 File format invalid; Sequence references a waveform that is not present.
lpErrorDoc.txt begin on an even sample pair boundary. 630 Arb Sequence Error; Unable to reset sequence on baseband board after change in file. WFM{value}:{name} A change was made to a waveform file being referenced by the sequencer that has made the current sequence invalid. It is likely that the file contains too few samples. Correct the file size or the lengths and offsets in single waveform sequences and reenable the personality. {value} is the number of the baseband board on which the error occurred.
lpErrorDoc.txt time. This error is reported when the user attempts to activate one type of modulation while the other is activated. The modulation type that was most recently requested will be turned on and the modulation that was on at the time will be turned off. 640 WB I/Q Settings conflict; WB I/Q and AM WB cannot be on at the same time: Mux I/Q path and WB I/Q path cannot be on simultaneously The modulation types I/Q and AM WB cannot be used at the same time.
lpErrorDoc.txt messages may clarify why this error was reported. 700 State Save Recall Error; Failed to save the instrument state. {name} The instrument could not save an instrument state. Previous error messages may clarify why this error was reported. 700 State Save Recall Error; Recall data from different FW revision. No instrument state change. {name} An attempt was made to recall a state that was saved with an incompatible version of the instrument firmware.
lpErrorDoc.txt Burst shape files must have two or more points for both the rise and the fall shape specification. 702 Load/Store Error; Invalid modulation file. The user modulation file is invalid. The file is either corrupt or is not a modulation file. 702 Load/Store Error; Unrecognized FIR file version. The file is either corrupt or is not a FIR file. 702 Load/Store Error; Unrecognized modulation file version. The user modulation file has an unrecognized version.
lpErrorDoc.txt Digital module: {name}. Report this error to Agilent Technologies. This error is reported when the FPGAs on the digital module FPGAs failed to be configured. The digital module will not work properly in this state. 801 Digital module VCO unlock error; The VCO on the digital module is unlocked. Check to make sure the clock settings are correct and the correct clock reference is connected. The VCO on the digital module is unlocked.
lpErrorDoc.txt valid, but old version of the interface FPGA. 808 Digital module unlock error; The output clock is not locked. The clock output may not be valid. Please make sure all references and clocks are connected and the module is set up properly. This error occurs when the output clock modules are not locked. This can occur when the externally supplied clock is not stable, the module is not set up properly, or the internal clock is not locked.