You must set EPC to Embed to enable IP connectivity. Otherwise, all uplink IP data
will be discarded.
When using the E6621A alone, (not connected to an 8960), the UE IP addresses are taken from the scenario
files or the settings made on the PXT user interface. In this case, you need to verify the BSE network
settings by selecting Config, Network Setup, IP Setup.
When using the E6621A connected to an 8960, see EPC Setup
for more information. Refer to “WCDMA/LTE
Inter-RAT Handovers on page 149
for more information.
Mode
BSE, SA
Range
Off | Embed
Preset
Off
State Saved
No
Initial S/W Revision
6.0
Key Path
Mode > BSE > Mode Setup
Control Mode
TTCN: Sets the PXT in a state where TTCN is part of the system.
Standalone: Sets the PXT so that it is operating without TTCN.
To switch between Standalone and TTCN mode, you must select Preset after either
event below occurs:
A scenario file is loaded and run in Standalone mode
TTworkbench has executed a test case in TTCN mode
Mode
BSE
Range
TTCN | Standalone
Preset
Standalone
State Saved
Dependencies and/or Couplings
Grayed out after you load a scenario file or after switching to TTCN
mode in TTworkbench.
Initial S/W Revision
6.0
Key Path
Mode > BSE > Mode Setup
CH Bandwidth
After loading the scenario file, you can overwrite the channel bandwidth using this menu key. Currently, the
PXT supports the following bandwidths:
FDD: 1.4 MHz, 3.0 MHz, 5.0 MHz, 10 MHz, 15 MHz, and 20 MHz.
TDD: 5.0 MHz, 10 MHz, 15 MHz, and 20 MHz.