User`s guide
Agilent PXT Wireless Communications Test Set
User’s Guide
43
Incremental
For UDPv4 and ICMPv4, the hexadecimal content of the payload of the packets can be set to increment
between transmissions. This is helpful in packet identification.
Key Path: Mode > BSE > Func > DTCH Test > Parameter > Payload Type
User Define
For UDP and ICMPv4, this selection enables you to define the sixteen bits of hex data, which are repeated
inside each packet payload sent to the UE.
Key Path: Mode > BSE > Func > DTCH Test > Parameter > Payload Type
(DTCH) Parameter (Key Menu 2)
Enables you to select the packet size and the total number of packets you wish to send.
Packet Size
Total Packet
Key Path: Mode > BSE > Func > DTCH Test > Parameter > More
Packet Size
Specifies the number of bytes you wish to send in each packet during DTCH test.
Key Path: Mode > BSE > Func > DTCH Test > Parameter > More
Total Packet Count
Specifies the total number of packets you wish to send during DTCH test. The preset value is 10,000,000
packets.
Key Path: Mode > BSE > Func > DTCH Test > Parameter > More
UE Power Control
Accesses the menus enabling you to send messages to the UE to increase or decrease the power it uses to
transmit.
Power Adjust (All Up)
Power Adjust (All Down)
Frame Configuration
Key Path: Mode >BSE > Func