User`s guide
Agilent PXT Wireless Communications Test Set
User’s Guide
38
UL/DL EARFCN
Sets the uplink and downlink EARFCN to the same value.
Table of UL/DL EARFCN Default Values for LTE Frequency Bands (TDD Only)
Parameter
Range
Default Value
UL/DL EARFCN 36025 – 36175 (Band 33)
36225 – 36325 (Band 34)
36357 – 36943 (Band 35)
36957 – 37543 (Band 36)
37575 – 37725 (Band 37)
37775 – 38225 (Band 38)
38275 – 38625 (Band 39)
38675 – 39625 (Band 40)
39675 – 41565 (Band 41)
41615 – 43565 (Band 42)
43615 – 45565 (Band 43)
45590 – 46589 (Band 44)
36100 (Band 33)
36275 (Band 34)
36650 (Band 35)
37250 (Band 36)
37650 (Band 37)
38000 (Band 38)
38450 (Band 39)
39150 (Band 40)
40620 (Band 41)
42590 (Band 42)
44590 (Band 43)
46090 (Band 44)
Mode
BSE, SA, TDD
Range
36000 to 45565
Preset
39150
Dependencies and/or Couplings This key is grayed out when:
• Setting Method is set to FREQ
•
Tech is set to FDD
Initial S/W Revision
6.3
Key Path
Freq
Freq – Key Menu 2
Tab Step
After selecting the frequency parameter you wish to set from the Freq – Key Menu 1, this tab step setting
determines the value that is added or subtracted when pressing the Inc or Dec front-panel keys,
respectively. These step keys are located on the front-panel just below the rotary knob.
Mode
BSE, SA
Units
Hz, kHz, MHz
Preset
10 MHz
Initial S/W Revision
6.0
Key Path
Freq > More