User`s guide
Agilent PXT Wireless Communications Test Set
User’s Guide
36
DL EARFCN
Sets the downlink EARFCN and uses the default separation for the selected frequency band as specified in
the 3GPP test specification 36.101 section 5.7.4 to calculate the correct value of UL EARFCN. This setting
automatically overwrites the UL EARFCN value and the Center(DL)Freq value.
Table of DL EARFCN Default Values for LTE Frequency Bands (FDD Only)
Parameter Range Default Value
DL EARFCN 25 – 575 (Band 1)
607 – 1193 (Band 2)
1207 – 1943 (Band 3)
1957 – 2393 (Band 4)
2407 – 2643 (Band 5)
2775 – 3425 (Band 7)
3457 – 3793 (Band 8)
3825 – 4125 (Band 9)
4175 – 4725 (Band 10)
4775 – 4925 (Band 11)
5017 – 5173 (Band 12)
5205 – 5255 (Band 13)
5305 – 5355 (Band 14)
5755 – 5825 (Band 17)
5875 – 5975 (Band 18)
6025 – 6125 (Band 19)
6175 – 6425 (Band 20)
6475 – 6575 (Band 21)
7525 – 7625 (Band 23)
7750 – 7989 (Band 24)
8090 – 8640 (Band 25)
8690 – 9039 (Band 26)
9040 – 9209 (Band 27)
9210 – 9659 (Band 28)
300 (Band1)
900 (Band2)
1575 (Band3)
2175 (Band4)
2525 (Band5)
3100 (Band7)
3625 (Band8)
3975 (Band9)
4450 (Band10)
4850 (Band11)
5095 (Band 12)
5230 (Band 13)
5330 (Band 14)
5790 (Band 17)
5925 (Band 18)
6075 (Band 19)
6300 (Band 20)
6525 (Band 21)
7600 (Band 23)
7870 (Band 24)
8365 (Band 25)
8865 (Band 26)
9125 (Band 27)
9360 (Band 28)
Mode
BSE, SA, FDD
Range
25 to 7989
Preset FDD: 300
TDD: None (grayed out)
Dependencies and/or Couplings This key is grayed out when:
• Setting Method is set to FREQ
•
Tech is set to TDD.
Initial S/W Revision
6.3
Key Path
Freq