25
B-Cell Ratio
Selects the ratio in percent of the relative power allocated to B-cell compared to A-cell. For example, if B-
cell is set to 100%, then A-cell is set to 0%.
Mode
BSE, SA
Range
0 to 100
Units
%
Preset
0%
Dependencies and/or Couplings
This setting is coupled to A-Cell Ratio.
Initial S/W Revision
6.0
Key Path
Config > Cell Setup
Cell Selection
Accesses the available parameters you can set to configure the selection of the cell.
Key Path: Config > Cell Setup
Cell Selection
Sets the active cell to which all other cell settings pertain. This includes the loading of scenario files
and the sending of any custom or other messages you initiate within the N6062A Protocol Message
Editor software.
Mode
BSE, SA
Range
Acell | Bcell
Preset
Acell
Initial S/W Revision
6.0
Key Path
Config > Cell Setup > Cell Selection
Copy PHY Parameter - Acell to Bcell
Copies the PHY layer parameters from cell A to cell B.
Note: This function is useful when using the PXT to emulate two cells simultaneously and the PHY
settings must be identical. See “Testing Two Cells Using One PXT” on page 165
for more information.
Key Path: Config > Cell Setup > Cell Selection
Copy PHY Parameter - Bcell to Acell
Copies the PHY layer parameters from cell B to cell A.
Note: This function is useful when using the PXT to emulate two cells simultaneously and the PHY
settings must be identical. See “Testing Two Cells Using One PXT” on page 165
for more information.
Key Path: Config > Cell Setup > Cell Selection
External Sync
Accesses the SIB8 Force Sync key,