User`s guide
Agilent PXT Wireless Communications Test Set
User’s Guide
19
Input Mode
Int: When set to internal, the front-panel inputs are active.
Ext: When set to external, the Input Source key is activated to enable selection from the rear panel inputs.
Mode
BSE, SA
Range
Int | Ext
Preset
Int
Initial S/W Revision
6.0
Key Path
Config > RF Setup > RF Input Control
Input Source
IF: When set to IF, the uplink rear panel inputs accept IF signals.
IQ: When set to IQ, the uplink inputs accept analog IQ signals and the downlink analog IQ outputs and
inputs are active.
Mode
BSE, SA
Range
IF | IQ
Preset
IF
Initial S/W Revision
6.0
Key Path
Config > RF Setup > RF Input Control
RF Select
Sets RF port.
Key Path: Config > RF Setup > RF Input Control
Ext Cell Select
Sets the cell (A or B) for which you are defining all parameters.
Mode
BSE, SA
Range
A-Cell | B-Cell
Preset
B-Cell
Initial S/W Revision
6.0
Key Path
Config > RF Setup > RF Input Control
RF Output Control
This menu key activates the following menu of functions:
RF DL Output
RF1 Front Output
RF2 Front Output