User`s guide
Agilent PXT Wireless Communications Test Set
User’s Guide
17
CONNECTED_ADJUSTER
This parameter is automatically set by the PXT when Attenuation is set to Adaptive.
This value is an adjustment applied to the expected input value when the UE is in the connected state.
Mode
BSE
Overwrites Scenario File Value
Yes
Range
-30 to 30
Units
dB
Preset
0
Dependencies and/or Couplings
Available only when Attenuation is set to Adaptive.
Initial S/W Revision
6.4
Key Path
Atten > More
OVF_ADJUSTER
This parameter is automatically set by the PXT when Attenuation is set to Adaptive.
If an overflow (OVF) is detected, as designated by the OVF light on the front-panel, this menu key enables
you to adjust the size of the automatic adjustments to the attenuation setting that will be made in Adaptive
mode to ensure accurate uplink power measurements are being made.
It should not be necessary for you to change the value of this parameter.
Mode
BSE
Overwrites Scenario File Value
Yes
Range
0 to 10
Units
dB
Preset
1
Dependencies and/or Couplings
Available only when Attenuation is set to Adaptive.
Initial S/W Revision
6.4
Key Path
Atten > More
BSE
In the Base Station Emulator (eNodeB emulation) mode, the PXT simulates an LTE eNodeB's operation for use
in the development and test of LTE UEs. In this mode, you test the UE by setting up a call and establishing a
link.
Key Path: Front-panel key (Note: You may have to press the Mode key to obtain the menu keys below.)
Emulator Mode
The eNodeB simulation starts and stops by pressing this menu key. If simulation has started, the
instrument is ready to be connected with the UE. When simulation stops, the instrument transmits only
default signals in the downlink and all the tests are frozen.
Key Path: Mode > BSE