User`s guide
Agilent PXT Wireless Communications Test Set
User’s Guide
238
Message Editor Field
PXT Menu Key
Key Path
MNC is carried in SIB1.
It also exists in the NAS Attach Accept
message:
• in the TAIList
• in the Globally Unique Temporary
Identity (GUTI), if it is present
and overwrites both of these values.
MNC
BSE > Mode Setup> More >
NAS Settings
This setting controls the number of digits of
MNC. It is carried in SIB1.
It also exists in the NAS Attach Accept
message:
• in the TAIList
• in the Globally Unique Temporary
Identity (GUTI), if it is present
and overwrites both of these values.
2 or 3 Digit MNC
BSE > Mode Setup> More >
NAS Settings
NAS Ciphering Algorithm controls the
Ciphering Algorithm selected for use in the
Non Access Stratum. This is signaled in the
EMM layer’s Security Mode Command.
NAS Ciphering
Algorithm
BSE > Mode Setup> More > NAS
Settings
This enables the EPS Bearer ID associated
with each of the configured Default EPS
Bearer Contexts in the scenario file to be
read back.
Default EPS Bearer
Config # 1 (-4)
BSE > Mode Setup> More > NAS
Settings
IP Address Type controls what type of IP
address is assigned to the UE in the
Activate Default EPS Bearer Context
Request message. You can assign an IPv4
address, an IPv6 address, or both an IPv4
and IPv6 to the UE.
IP Address Type
BSE > Mode Setup> More > NAS
Settings > Default EPS Bearer
Config #(1-4)
V4 Address controls the IPv4 address that
is assigned to the UE in the Activate
Default EPS Bearer Context Request
message, if the IP Address Type selection
has enabled this.
V4 Address
BSE > Mode Setup> More > NAS
Settings > Default EPS Bearer
Config #(1-4)
V6 Address controls the IPv4 address that
is assigned to the UE in the Activate
Default EPS Bearer Context Request
message, if the IP Address Type selection
has enabled this.
V6 Address
BSE > Mode Setup> More > NAS
Settings > Default EPS Bearer
Config #(1-4)