User`s guide
Agilent PXT Wireless Communications Test Set
User’s Guide
201
Channel Power Measurement (TDD Example)
Key Path:
Mode > SA > LTE > Channel Power
Figure 6-6: Channel Power measurement (TDD Example)
Notice the power levels are only present on subframes 2, 3, 7, and 8. This is because the UE only transmits
on those subframes, when using TDD. For this example, the UL-DL configuration selected is 6.
You can graphically display any of the 10 measured subframes by pressing Meas Setup > Display Interval.
Subframe #2 is displayed in this example.
Measurement Setup
Select the Meas Setup front-panel key to select which subframe power measurement to display. To edit
the interval duration, press Edit Interval. You must set Interval to On in order to change any other
settings in this menu. Set the Start Time and Duration in µsec. The resolution bandwidth is set by the
Measurement BW setting.