User`s guide
Agilent PXT Wireless Communications Test Set
User’s Guide
187
Figure 5 - 14: TargetRAT Message Container = Hex as Extracted via SCPI from 8960
9. Add this message to the ‘Handover Message List’ on the Extended tab.
10. Save the scenario file.
The scenario file is now ready for the SRVCC test. The above Phase 1 is only required to create the mobility message,
and does not need to be performed again unless the 8960 configuration changes.
Phase 2 – SRVCC Execution
1. Repeat steps 1-6 from phase 1 to create the IMS call and move the 8960 to the handover state.
7. Issue the SRVCC handover message on the PXT by selecting Func > Handover > Message Name > (name
as created in the scenario file) > Send.