User`s guide
Agilent PXT Wireless Communications Test Set
User’s Guide
148
• OCNG
• Downlink Power Control
• RCT
• CQI Median
Refer to Func menu key on page 39
for more information.
DTCH Test
For the downlink data transmission test, select Func, DTCH Test. The packet to be transmitted is
configured by selecting the Parameter menu. Data format, network interface, transfer rate, payload type,
packet size, and numbers of packets to be transmitted are all set in this menu. The test results are viewed
on the ER/Throughput display by selecting Meas.
After configuring the necessary parameters for this measurement, select Test (On). If Transfer Mode
(Auto) is selected, the data transmission starts automatically. Setting Transfer Mode to Manual, requires
that you select Manual Transfer in the sub-menu to transfer the packet.
UE Power Control
To test the power control function, select Func, UE Power Control. You can send a power control message
(Send Message), set the DCI Format and set the power control to All Up or All Down
.
Handover, UE Detach, Paging, Custom Message
To perform these functional tests, the message to be sent is edited using the N6062A Protocol Message
Editor software and is included in each field. The menu keys are configured when the scenario is loaded.
In each field, multiple rrcConnectionReconfiguration messages can be included, for various protocol or
radio tests.
PDCCH Order
Refer to PDCCH Order for more information.
OCNG
Refer to OCNG for more information.
Downlink Power Control
Refer to UE Power Control for more information.
RCT
Refer to RCT for more information.
CQI Median
Refer to OCNG for more information.