User`s guide
Agilent PXT Wireless Communications Test Set
User’s Guide
145
the connection from the appropriate page on the 8960. Before continuing, be sure that the 8960 reports the
EPC Connection Status as “Connected”.
Gateway Setting:
This is where all UE uplink IP data is directed during inter-RAT testing, regardless to which subnet the IP
data is destined. So, when setting up the IRAT handover procedure, this IP address is the target for 8960
UE IP traffic, and typically this is set to the “Server” PC IP address. (You can also set it to a corporate LAN
“Default Gateway”.)
8960: LAN IP Address 2(Data+):
This is the IP address of the 8960. For correct operation, both 8960 LAN1 and LAN2 ports must be
connected and allocated IP addresses. On the 8960, the value set for the ‘LAN IP Address 2 (Data+)’
setting should also be entered here.
This is not an essential field if the expected operation is to initiate the
connection from the 8960.
Alternative UE IP-IPv4Range:
This is the IPv4 address range used when the UE requests an IPv4 address when attached to the 8960.
Note that this should match any scenario file in use for inter-RAT handovers.
Alternative UE IP-IPv6 IID Range:
This is the IPv6 address range used when the UE requests an IPv6 address when attached to the 8960.
Note that this should match any scenario file in use for eHRPD inter-RAT handovers.
Non Local Prefix: This is the IPv6 network prefix which is used for the UE when not link-local.
Bindings
When you select this option from the EPC menu, all bindings listed:
• are currently active in the EPC
• have an associated EPS_BID identifier
Every time the EPC receives and uplink packet containing and IPv6 source address, the PXT ensures that
binding occurs and this list is updated. When the dedicated radio bearer (DRB) is removed or the Default
EPS Bearer Context is removed, the bindings associated with that EPS Bearer Context are also removed
and no longer displayed in this list.