User`s guide

Agilent PXT Wireless Communications Test Set
User’s Guide
118
Initial S/W Revision 6.4
Available for TDD in 6.5.
Key Path
BSE > Mode Setup> More > RRC Settings > Timers
Inactivity Timer
If the Inactivity Timer is turned On, this setting sets the number of seconds the UE remains in the RRC
Connected state while not transferring any data on an SRB or DRB before the PXT sends an RRC
Connection Release to it.
Mode
BSE
Range
1 to 100
Preset
10
Initial S/W Revision 6.4
Available for TDD in 6.5.
Key Path
BSE > Mode Setup> More > RRC Settings > Timers
Additional Spectrum Emission
Controls how much leakage the UE is allowed into adjacent frequencies. This setting is contained in SIB2.
This setting overwrites the value defined in the currently loaded scenario file, when the
BSE emulator is not running (Mode > BSE > Emulator Mode = Stop
is selected).
Mode
BSE, FDD
Overwrites Scenario File Value
Yes
Range
1-32 (Integer only)
Preset
1
Initial S/W Revision
6.3
Key Path
BSE > Mode Setup> More > RRC Settings
SIB1
UL DL Configuration
This parameter controls how many subframes are used for DL transmission, how many for UL transmission,
and how many are special subframes (used for both). It appears in the SIB1, with the name
subframeAssignment.
Mode
BSE, TDD
Overwrites Scenario File Value
Yes
Range
0 - 6
Preset
1
Initial S/W Revision 6.4
Subframe 0 supported in 6.5.
Key Path
BSE > Mode Setup> More > RRC Settings More > More > SIB1