User`s guide
Agilent PXT Wireless Communications Test Set
User’s Guide
112
p-Max
The p-Max value is carried in SIB1 and determines the maximum power that the UE is allowed to transmit.
This setting overwrites the value defined in the currently loaded scenario file, when the
BSE emulator is not running (Mode > BSE > Emulator Mode = Stop
is selected).
Mode
BSE
Overwrites Scenario File Value
Yes
Range
−30 to 33
Preset
23
Initial S/W Revision
6.3
Key Path
BSE > Mode Setup> More > RRC Settings
p0-NominalPUSCH
This value contributes towards the power of the PUSCH and is carried in SIB2.
This setting overwrites the value defined in the currently loaded scenario file, when the
BSE emulator is not running (Mode > BSE > Emulator Mode = Stop
is selected).
Mode
BSE
Overwrites Scenario File Value
Yes
Range
−126 to 24
Preset
−85
Initial S/W Revision
6.3
Key Path
BSE > Mode Setup> More > RRC Settings
p0-UE-PUSCH
This value contributes towards the PUSCH power and is carried in RRC Connection Setup message.
This setting overwrites the value defined in the currently loaded scenario file, when the
BSE emulator is not running (Mode > BSE > Emulator Mode = Stop
is selected).
Mode
BSE
Overwrites Scenario File Value
Yes
Range
−8 to 7 (Integer)
Preset
0
Initial S/W Revision
6.3
Key Path
BSE > Mode Setup> More > RRC Settings