User`s guide
150 E6651A User’s Guide
6 Remote Interface (API) Programming Command Reference
Power Control Test
E6651_GetPCEIRP
Declaration int E6651_GetPCEIRP(BYTE MID, int * Value);
Parameter
MID [in]: E6651’s equipment number to be controlled
remotely.
Value [out]: Current DCD message’s EIRP of E6651(MID).
Return Value
Success: STATE_SUCCESS(1)
Failure: STATE_ERROR(- 1)
Description Retrieve DCD message’s EIRP of E6651(MID).
E6651_SetPCEIRP
Declaration int E6651_SetPCEIRP(BYTE MID, int Value);
Parameter
MID [in]: E6651’s equipment number to be controlled
remotely.
Value [in]: EIRP value of E6651(MID) to be set in DCD
message.
Return Value
Success: STATE_SUCCESS(1)
Failure: STATE_ERROR(- 1)
Description Set EIPR value of E6651(MID) in DCD message.
E6651_GetPCEIRxP
Declaration int E6651_GetPCEIRxP(BYTE MID, int * Value);
Parameter
MID [in]: E6651’s equipment number to be controlled
remotely.
Value [out]: Current DCD message’s Earwax IR, max
value of E6651(MID)
Return Value
Success: STATE_SUCCESS(1)
Failure: STATE_ERROR(- 1)
Description Retrieve DCD message’s EIRxP IR, max value of E6651(MID).