User`s guide

132 E6651A User’s Guide
6 Remote Interface (API) Programming Command Reference
E6651_SetBSRNGRSP_Status
Declaration int E6651_SetBSRNGRSP_Status(BYTE MID, int
Value);
Parameter
MID [in]: E6651’s equipment number to be controlled
remotely.
Value [in]: State value of RNG- RSP msg. Transmission
Mode to be set.
Return Value
Success: STATE_SUCCESS(1)
Failure: STATE_ERROR(- 1)
Description Set State value of Initial Ranging’ Result Transmission Mode.
E6651_SetBSRNGRSP_Status sets:
0 if Transmission mode is changed ‘Success’ or ‘Continue’ by
current rule when a mobile phone is trying Initial Ranging.
1 if Transmission mode is always ‘Success’ when a mobile
phone is trying Initial Ranging.
2 if Transmission mode is always ‘Continue’ when a mobile
phone is trying Initial Ranging.
3 if Transmission mode is always ‘Abort’ when a mobile
phone is trying Initial Ranging.
E6651_GetDLMAPRepetition
Declaration int E6651_GetDLMAPRepetition(BYTE MID, int *
Value);
Parameter
MID [in]: E6651’s equipment number to be controlled
remotely.
Value [out]: Current DL MAP Repetition value of
E6651(MID).
Return Value
Success: STATE_SUCCESS(1)
Failure: STATE_ERROR(- 1)
Description Retrieve DL MAP Repetition value of E6651(MID).