User`s guide
Remote Interface (API) Programming Command Reference 6
E6651A User’s Guide 109
E6651_GetUIQNegHalfAvgPower
Declaration int E6651_GetUIQNegHalfAvgPower(BYTE MID, double
* Value);
Parameter
MID [in]: E6651’s equipment number to be controlled
remotely.
Value [out]: Average power of sub- carriers (sub- carrier
interval:- N to - 1) when E6651(MID) is
operating in Uplink Flatness Measure Mode.
Return Value
Success: STATE_SUCCESS(1)
Failure: STATE_ERROR(- 1)
Description Retrieve Average power within sub- carrier interval of –N to
- 1 when E6651(MID) is operating in Uplink Flatness Measure
Mode.
E6651_GetUIQPosHalfAvgPower
Declaration int E6651_GetUIQPosHalfAvgPower(BYTE MID, double
* Value);
Parameter
MID [in]: E6651’s equipment number to be controlled
remotely.
Value [out]: Average power of sub- carriers (sub- carrier
interval:+N to +1) when E6651(MID) is
operating in Uplink Flatness Measure Mode.
Return Value
Success: STATE_SUCCESS(1)
Failure: STATE_ERROR(- 1)
Description Retrieve Average power within sub- carrier interval of +N to
+1 when E6651(MID) is operating in Uplink Flatness Measure
Mode.