Technical data

186 Chapter 13
GSM/EDGE Programming Commands
GSM Loopback BER
GSM/EDGE Programming Commands
GSM Loopback BER
This section provides the remote control SCPI commands for the GSM Loopback BER measurement
from within the List Sequencer. This measurement is available only if you have the GSM/EDGE
measurement application licensed on the test set.
The GSM Loopback BER measurement is based on the GMSK Phase and Frequency (PFER)
measurement, and uses remote commands associated with that measurement.
For more detailed information about the GMSK Phase and Frequency measurement, refer to the online
help associated with the GSM/EDGE measurement application, which is also available in PDF format
(“Users and Programmers Reference”) on the Agilent website, www.agilent.com/find/e6640a.
Loopback BER measurement SCPI commands
The following commands are used to set up the Loopback BER measurement from within the sequence
analyzer mode.
[:SENSe]:LSEQuencer:EDGE:PFERror:BSYNc:SOURce
NOTE “EDGE” (and not “GSM”) is used to designate the GSM/EDGE mode in commands
Loopback BER results
Index Result Parameter
0 Loopback bit error ratio.
1 Total tested bit number.
2 Failed bit number.
3 Reserve.