Performance
Capture depth 4 GB memory, 512 MSa of IQ data
Frequency and time specications
Frequency range
All RF ports (options are per TRX module)
Option E6640A-504
Option E6640A-5WC
Option E6640A-506
380 MHz to 3.8 GHz
1.1 to 1.8 GHz, 2.3 to 2.6 GHz, and 4.8 to 6.0 GHz
380 MHz to 6.0 GHz
Specied frequency range (dependent on selected frequency range option)
380 to 495 MHz
695 to 920 MHz
1425 to 1485 MHz
1620 to 2030 MHz
2300 to 2700 MHz
3400 to 3800 MHz
4900 to 6000 MHz
Frequency reference
Accuracy, aging rate, stability Refer to Timebase Specications
CW measurement frequency accuracy
Accuracy (Transmitter frequency x frequency reference accuracy) ± 50 Hz typical
Resolution 1 Hz typical
Analysis bandwidth
Maximum bandwidth
E6640A-B40
E6640A-B85
380 to 495 MHz
695 to 800 MHz
All other specied frequency ranges
Up to 40 MHz analysis bandwidth
Up to 40 MHz
Up to 60 MHz
Up to 80 MHz
E6640A-B1X
380 to 495 MHz
695 to 800 MHz
3400 to 3800 MHz
All specied frequency ranges
Up to 40 MHz
Up to 60 MHz
Up to 100 MHz
Up to 160 MHz
Triggering
Trigger
Sequence analyzer
IQ analyzer
Free run, external 1, external 2, RF burst, video, internal
Free run, external 1, external 2, RF burst, video, line, periodic
Trigger delay range 15 to 500 ms
Resolution 0.1 μs
Amplitude accuracy and range specications
Input level ranges (average power)
RF3 I|O and RF4 I|O (half duplex) 70 to +30 dBm
RFIO1 and RFIO2 (full duplex) –65 to +36 dBm
Vector signal analyzer performance
08 | Keysight | E6640A EXM Wireless Test Set - Data Sheet