Keysight Technologies

dataTec ▪  Ferdinand-Lassalle-Str. 52  ▪  72770 Reutlingen  ▪  Tel. 07121 / 51 50 50  ▪  Fax 07121 / 51 50 10  ▪  info@datatec.de  ▪  www.datatec.de
19
V9081B Bluetooth
®
measurement application key specications
1
Channel power
Absolute power accuracy ±0.26 dB typical at 0 dBm input power
Modulation characteristics
Deviation range ±250 kHz nominal
EDR modulation accuracy
Range (rms DEVM) 0 to 12% nominal
Floor 0.6% typical at –20 dBm input power
Bluetooth source key specications
2
Bluetooth source performance
Bluetooth signal using Signal Studio waveform
Basic data rate (ACL)
FSK error at –10 dBm at RF I|O ports 0.65% nominal, DH1 packet, GFSK, standard packet, 2402 MHz
Enhanced data rate
ACP for –10 dBm signal at RF I|O ports 3-DH1 packet, GFSK +D8PSK, standard packet, 2402 MHz
–69 dBm nominal, k=2
72 dBm nominal, k= 3, 4, 5, …78
EDR rms DEVM error < 1% nominal
1. Specications apply for frequencies between 2400 and 2486 MHz
2. For specied frequency ranges between 1620 and 2700 MHz
Application Specications (continued)
19 | Keysight | E6640A EXM Wireless Test Set - Data Sheet