V9072B cdma2000
®
and V9076B 1xEV-DO measurement application key specications
1
Channel power
Absolute power accuracy ±0.36 dB typical at 0 dBm input power
Error vector magnitude (EVM)
Residual EVM 0.85% typical at –10 dBm input power
Adjacent channel power (ACP)
Residual relative power in 30 kHz bandwidth (offsets)
885 kHz –71 dBc typical at 0 dBm input power
1.98 MHz –83 dBc typical at 0 dBm input power
4.0 MHz –82 dBc typical at 0 dBm input power
cdma2000 and 1xEV-DO source key specications
2
Signal quality (RF I|O ports: 0 dBm, RFIO ports: –15 dBm)
Composite EVM
RMS < 1.1% nominal
1. For frequencies from 410 to 484 MHz, 776 to 920 MHz, and 1710 to 1980 MHz
2. For frequencies from 380 to 490 MHz, 695 to 960 MHz, and 1425 to 2180 MHz
Application Specications (continued)
17 | Keysight | E6640A EXM Wireless Test Set - Data Sheet