User`s guide
System Information D
Agilent E6474A User’s Guide 181
Battery Specifications (part of E6473B, options 022, 023, and 024)
Item Description Specifications
Part Number E6473-60008
Ty pical C apaci t y 9000 mAh
Nominal Voltage 14.4V
Discharge Cut-off voltage 12.0V
Cell Configuration five in parallel and four series
Allowable Temperature Range -20º C to +60º C at discharge
0º C to 40º C at charge
Storage Temperature Range -20º C to 50º C 3-month
-20º C to 35º C 6-month
-20º C to 20º C 12-month
Humidity 0 to 85%
Weight 2.33 lbs. / 1.057 kg
Te r m i n a l s Discharge - Molex 15-24-6047
Charge - HCH No.IDJ-D22-6T
Overcharge Protection Charging turned off at and over 4.35 V/cell
+\- .05 mV
Charging re-enabled at and under 4.1 V/cell
+/- 50 mV
Charging off at nominal 4.2 V/cell with
charge current <= 00 mA
Over Discharge Protection Discharge off at and lower 2.35V / Cell
Discharge re-enabled at and higher 3.05
V/Cell
Shut Down at nominal 9.4V
Wake at recharge
Short Circuit Protection: Off at short circuit