Specifications
30
Avg Rev Traffic T’put – Average throughput for the reverse traffic channel as a
function of the number of reverse link traffic packets transmitted at various rates
Tx Power – Total TX power as determined by the entire TX AGC mechanism
PER – Instantaneous Packet Error Rate
Receiver-based software
The Agilent E6474A software option 111 (receiver only license) or 121 (phone and
receiver license) provide the functions described below. The receiver measurement
functions of the Agilent E6474A system is provided by either option 111 and 121. Either
software option, combined with the appropriate receiver hardware option, allows four
primary elements:
CDMA Pilot Channel Analysis
Spectrum Analysis
CW Power
Channel Power
Each element has an associated control view and display view. The software can control
up to four Agilent digital RF receivers. The controls listed below are available for the
receiver measurements:
Measurement interval
-Time
- Distance
Averaging
- Running
- Group
- Max Hold
- At Least (CW and channel power only)
The measurement interval defines the duration between measurements. This can be
specified in terms of time (e.g., execute a measurement every 200 milliseconds) or
distance (e.g., execute a measurement every 10 meters). If the user defines an interval
that the system can not achieve, a busy light indicates this condition.