User`s guide
Chapter 2 45
Using Functions
Testing a Mobile with MANUAL TEST (GPRS mode)
2. Using Functions
At one field, press the CURSOR CONTROL knob, then rotate it. You see that field
changes its values. Press the CURSOR CONTROL knob to enter that value.
Step 7. Specify the higlighted fields of the test parameters as shown in the above screen.
If you want to supply dc power from the Test Set to the mobile, set the DC Power
field to On and enter your desired voltage value. To do this, use the Universal DC
Power Adapter and an appropriate dc power cable to connect between the AUX
port of the Test Set and the mobile.
Step 8. Press the Return, CONFIGURATION, then Test Setup softkeys to obtain the Test
Setup: Test Condition screen shown below.
Step 9. Specify the highlighted fields of the test parameters as shown in the left side of the
above screen.
Step 10. Enter the appropriate limits in the cells of the test item table above. For testing
BLER it is required to set the upper limit value.
Step 11. After you have set all parameters, press the Return, Return again, then MANUAL
TEST softkeys to obtain the MANUAL TEST: Stand-by screen shown below.
Check if the Mode Sync/Async/GPRS softkey is set to GPRS
.
Step 12. Turn the mobile on and wait for it to camp on displaying 001-01.
Step 9 Step 10