User`s guide
Chapter 3 121
Screen Reference
MANUAL TEST (GPRS Mode)
3. Screen Reference
DC Power
Selects a supply mode. The choices are On and Off as follows:
o On: Always supplies dc voltage to the mobile.
oOff:
b
Disables to supply dc voltage to the mobile.
Accepts a dc voltage value
a
ranging from 3.0 to 11.0 V in 0.1 V
steps. This value is used among the AUTOMATIC TEST,
MANUAL TEST, SPECTRUM MONITOR, and SIGNAL
GENERATOR modes in common.
Signal
For synchronous mode tests, only Burst is valid and cannot be
changed.
BS Level Specifies the RF output level
a
of the Test Set, ranging from −110.0
to −50.0 dBm. The default value is set on the Test Condition screen
in the CONFIGURATION mode.
Timing ADV Accepts a value for the timing advance
a
ranging from 0 to 63 bits.
Slot Config
Selects either 1 (downlink) × 1 (uplink) or 2 × 1 if Option 040 is
installed.
Measured Slot
The order of measured slot is defaulted to 4 (fourth) if Option 040
is installed.
Sensitivity
Displays BLER (block error rate) to make a sensitivity
measurement.
a. The variable increment softkey is activated. Refer to "Variable Incre-
ment Softkey" on page 60.
b. When DC Power is set to Off, DC Current cannot be measured.
Input Field Description