User`s guide

Chapter 3 111
Screen Reference
MANUAL TEST (Asynchronous Mode)
3. Screen Reference
Measuring: Phase Error/Frequency Error
The RMS and Peak Phase Errors and Frequency Error are shown, along with the
marker readouts if the marker is activated. If the actual data exceeds the limits in
the graph, one (or two for two fails) white triangle marker indicates the failed
position at the top of the graph frame. Any data indicating a failure is highlighted.
Figure 3-39 Aborted: Phase Error/Frequency Error Screen
Softkey Menu 1
o Start: Begins a new test.
o Trigger Sing/Cont: Toggles the trigger mode between Sing
for single and
Cont
for continuous modes. In the continuous mode, this softkey is
highlighted blinking until the Abort softkey is pressed. In the single mode,
this softkey is highlighted for one measurement cycle and the marker
function is available with the Knob MKR/Cursor softkey.
o More (1 of 3): Displays softkey menu 2.
o Return: Returns to the initial Measuring screen as shown in Figure 3-35.
Softkey Menu 2
o Knob MKR/Cursor: Toggles the function of the CURSOR CONTROL knob
between Cursor
and MKR for marker control.
o Marker Coars/Fine: Toggles the marker control between Coars
for coarse
and Fine
to move the marker with 10 dots (coarse) or 1 dot (fine) resolution.
The marker readouts for the phase error magnitude and timeslot (in bits) are
available at any point of the measured trace.
o More (2 of 3): Displays softkey menu 3.
o Return: Returns to the initial Measuring screen as shown in Figure 3-35.
Softkey Menu 3
o Print: Allows you to print a hardcopy of a graphic image from the screen.
o More (3 of 3): Returns to softkey menu 1.