Specifications

Table Of Contents
98 Chapter 3
Programming Command Reference
TESTs Subsystem for MANUAL TEST
This command specifies the frequency of Traffic Channel (TCH) to be tested, for
each of the radio standards in conjunction with the Multi Band settings. The
allowable range and preset values are as follows:
Command Reference for Phase/Frequency Error Measurement Screen
The PHASe commands are used to set the controls and parameters associated with
the Phase Error and Frequency Error measurements and the pass/fail tests.
Send the "DISPlay:MANual:PHASe" command to display the Phase
Error/Frequency Error Measurement screen for MANUAL TEST before sending
the following commands.
Averaging Function
TESTs:MANual:PHASe:AVERage OFF|<int>
TESTs:MANual:PHASe:AVERage?
This command defines whether or not to activate the averaging function. The
choices are OFF and <int> for averaging time. The allowable range of <int> is
from 2 to 99. At preset, this is set to OFF.
BS Level
TESTs:MANual:PHASe:AMPLitude <real> [dBm]
TESTs:MANual:PHASe:AMPLitude?
This command specifies an amplitude of BS Level. The allowable range is from
110.0 to 50.0 (dBm) in 0.5 steps. At preset, this is set to 50.0 (dBm).
RFORmat MBANd Allowable Range [Hz] Preset Value [Hz]
GSM900 DCS1800 890200000 to 914800000;
1710200000 to 1784800000
896000000
OFF 890200000 to 914800000
E-GSM DCS1800 880200000 to 914800000;
1710200000 to 1784800000
896000000
OFF 880200000 to 914800000
DCS1800 GSM900 1710200000 to 1784800000;
890200000 to 914800000
1710200000
E-GSM 1710200000 to 1784800000;
880200000 to 914800000
OFF 1710200000 to 1784800000
PCS1900 OFF 1850200000 to 1909800000 1850200000