Specifications
Table Of Contents
- E6392-90042.pdf
- E6392-90042_manual
- Front Matter
- Contents
- 1 Preparing for Use
- 2 Programming Command Guidelines
- 3 Programming Command Reference
- IEEE Common Command
- CONFigure Subsystem
- DISPlay Subsystem
- HCOPy Subsystem
- RFGenerator Subsystem
- SMONitor Subsystem
- SYSTem Subsystem
- TESTs Subsystem for AUTOMATIC TEST
- All Tests Results
- All Tests Results
- Command Reference for Burst Timing/Power Ramp Measurement Screen
- Command Reference for DC Current Measurement Screen
- Command Reference for MS Information
- Command Reference for Peak TX Power Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Stand-by/Measuring Screens
- TESTs Subsystem for MANUAL TEST
- Command Reference for DC Current Measurement Screen
- Command Reference for Measuring Screens
- Command Reference for MS Information
- Command Reference for Peak TX Power /Burst Timing/Power Ramp Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Spectrum Monitor Measurement Screen
- Command Reference for Stand-by Screens
- TRIGger Subsystem
- 4 Programming Command Cross Reference
- 5 Example Programs
- A Syntax Diagram
- B Command Difference between E6392A & E6392B
- Index

94 Chapter 3
Programming Command Reference
TESTs Subsystem for MANUAL TEST
NOTE For Test Sets with Option 040, if the mode is set to GPRS, this
measurement screen is titled as Peak TX Power/Power vs Time.
Actual Timing Advance
TESTs:MANual:TXAMplitude:ACTAdvance?
This command queries the value of Actual Timing Advance.
NOTE For Test Sets with Option 002, if the mode is set to SYNC, this
command is valid.
For Test Sets with Option 002 and Option 040, if the mode is set to
SYNC or GPRS, this command is valid.
Averaging Function
TESTs:MANual:TPOWer:AVERage OFF|<int>
TESTs:MANual:TPOWer:AVERage?
This command defines whether or not to activate the averaging function. The
choices are OFF and <int> for averaging time. The allowable range is from 2 to 99.
At preset, this is set to OFF.
BS Level
TESTs:MANual:TPOWer:AMPLitude <real> [dBm]
TESTs:MANual:TPOWer:AMPLitude?
This command specifies an amplitude of BS Level. The allowable range is from
−110.0 to −50.0 (dBm) in 0.5 steps. At preset, this is set to −50.0 (dBm).
Burst Timing Measurement
TESTs:MANual:TXAMplitude:RESults:BTIMing?
This query command returns a set of values, <string 1>, <string 2> and
<string 3>, for Burst Timing tests.
• <string 1> (1 digit) is 0 when all values are within the normal range, or 1 if any
measurement is overranged, underranged or not made.
• <string 2> (1 digit) is the binary data, 0 or 1, for the pass (0) or fail (1) result.
• <string 3> (4 digits) is the measured timing value in bits ranging from −9.9 to
+9.9. If its measurement is overranged, underranged or not made, the value
−9.9 is returned.
DC Power Voltage
TESTs:MANual:TPOWer:DCPower:VOLT <real> [V]
TESTs:MANual:TPOWer:DCPower:VOLT?