Specifications
Table Of Contents
- E6392-90042.pdf
- E6392-90042_manual
- Front Matter
- Contents
- 1 Preparing for Use
- 2 Programming Command Guidelines
- 3 Programming Command Reference
- IEEE Common Command
- CONFigure Subsystem
- DISPlay Subsystem
- HCOPy Subsystem
- RFGenerator Subsystem
- SMONitor Subsystem
- SYSTem Subsystem
- TESTs Subsystem for AUTOMATIC TEST
- All Tests Results
- All Tests Results
- Command Reference for Burst Timing/Power Ramp Measurement Screen
- Command Reference for DC Current Measurement Screen
- Command Reference for MS Information
- Command Reference for Peak TX Power Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Stand-by/Measuring Screens
- TESTs Subsystem for MANUAL TEST
- Command Reference for DC Current Measurement Screen
- Command Reference for Measuring Screens
- Command Reference for MS Information
- Command Reference for Peak TX Power /Burst Timing/Power Ramp Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Spectrum Monitor Measurement Screen
- Command Reference for Stand-by Screens
- TRIGger Subsystem
- 4 Programming Command Cross Reference
- 5 Example Programs
- A Syntax Diagram
- B Command Difference between E6392A & E6392B
- Index

90 Chapter 3
Programming Command Reference
TESTs Subsystem for MANUAL TEST
Signaling State (GPRS mode)
TESTs:MANual:MEASure:SIGNaling:STATe?
This query command returns a value, <string>, corresponding to the test flow
steps executed for a test cycle for the GPRS mode as follows:
bit 0 (1): Idle
bit 1 (2): Attached
bit 2 (4): Connect
bit 3 (8): Time Out Error
bit 4 (16): Measurement End
The choices for each bit are 1 for executed and 0 for not.
NOTE If the mode is set to SYNC on the Test Set with Option 040, this
command is invalid.
Signaling State (SYNC mode)
TESTs:MANual:MEASure:SIGNaling:STATe?
This query command returns a value, <string>, corresponding to the test flow
steps executed for a test cycle as follows:
bit 0 (1): MS Call/BS Call
bit 1 (2): Talk/RF Test
bit 2 (4): MS Release/BS Release
bit 3 (8): Time Out Error
bit 4 (16): Measurement End
The choices for each bit are 1 for executed and 0 for not.
NOTE For Test Sets with Option 002, if the mode is set to ASYNC, this
command is invalid.
If the mode is set to GPRS on the Test Set with Option 040, this
command is invalid.
Slot Configuration
TESTs:MANual:MEASure:SCONfigure 1×1|2×1
This command specifies the slot combination for downlink and uplink,
respectively, in the Measuring screen for the GPRS mode, in conjunction with the
Slot Measured setting. The combinations of the slot configuration and the slot
order measured are as follows: