Specifications
Table Of Contents
- E6392-90042.pdf
- E6392-90042_manual
- Front Matter
- Contents
- 1 Preparing for Use
- 2 Programming Command Guidelines
- 3 Programming Command Reference
- IEEE Common Command
- CONFigure Subsystem
- DISPlay Subsystem
- HCOPy Subsystem
- RFGenerator Subsystem
- SMONitor Subsystem
- SYSTem Subsystem
- TESTs Subsystem for AUTOMATIC TEST
- All Tests Results
- All Tests Results
- Command Reference for Burst Timing/Power Ramp Measurement Screen
- Command Reference for DC Current Measurement Screen
- Command Reference for MS Information
- Command Reference for Peak TX Power Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Stand-by/Measuring Screens
- TESTs Subsystem for MANUAL TEST
- Command Reference for DC Current Measurement Screen
- Command Reference for Measuring Screens
- Command Reference for MS Information
- Command Reference for Peak TX Power /Burst Timing/Power Ramp Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Spectrum Monitor Measurement Screen
- Command Reference for Stand-by Screens
- TRIGger Subsystem
- 4 Programming Command Cross Reference
- 5 Example Programs
- A Syntax Diagram
- B Command Difference between E6392A & E6392B
- Index

82 Chapter 3
Programming Command Reference
TESTs Subsystem for AUTOMATIC TEST
• If set to AUTO, DC Power is supplied during a measurement cycle or until a
measurement is aborted.
• If set to ON, DC Power is always supplied.
• If set to OFF, DC Power is not supplied and the variable of the six
measurements is automatically set to TCH.
DC Power Voltage
TESTs:AUTO:DCPower:VOLT <real> [V]
TESTs:AUTO:DCPower:VOLT?
This command specifies a voltage value of DC Power. The allowable range is from
3.0 to 11.0 (V) in 0.1 steps. At preset, this is set to 3.0 (V).
Multi Band
TESTs:AUTO:MBANd DCS1800|OFF
TESTs:AUTO:MBANd?
This command specifies whether or not to include the multi-band mobile tests for
DCS1800 when GSM900 or E-GSM is specified by the Radio Format command.
TESTs:AUTO:MBANd GSM900|E-GSM|OFF
TESTs:AUTO:MBANd?
This command specifies whether or not to include the multi-band mobile tests for
GSM900 or E-GSM when DCS1800 is specified by the Radio Format command.
If PCS1900 is specified with the Radio Format command, the Multi Band
command is automatically disabled (set to OFF).
Radio Standard
TESTs:AUTO:RFORmat GSM900|E-GSM|DCS1800|PCS1900
TESTs:AUTO:RFORmat?
This command defines a system of Radio Standard to be tested. The choices are
GSM900, E-GSM, DCS1800, and PCS1900. If PCS1900 is selected, the Multi
Band command is automatically set to OFF. At preset, this is set to GSM900.
Screen Mode
TESTs:AUTO:SCReen SIMPlified|DETailed
This command selects the screen mode. The choices are SIMPlified screen and the
DETailed screen. At preset, this value is set to SIMP.
Signaling State
TESTs:AUTO:MEASure:SIGNaling:STATe?
This query command returns a 9-bit binary coded decimal corresponding to the test
flow steps executed for a test cycle as follows:
bit 0 (1): LOC. Update