Specifications
Table Of Contents
- E6392-90042.pdf
- E6392-90042_manual
- Front Matter
- Contents
- 1 Preparing for Use
- 2 Programming Command Guidelines
- 3 Programming Command Reference
- IEEE Common Command
- CONFigure Subsystem
- DISPlay Subsystem
- HCOPy Subsystem
- RFGenerator Subsystem
- SMONitor Subsystem
- SYSTem Subsystem
- TESTs Subsystem for AUTOMATIC TEST
- All Tests Results
- All Tests Results
- Command Reference for Burst Timing/Power Ramp Measurement Screen
- Command Reference for DC Current Measurement Screen
- Command Reference for MS Information
- Command Reference for Peak TX Power Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Stand-by/Measuring Screens
- TESTs Subsystem for MANUAL TEST
- Command Reference for DC Current Measurement Screen
- Command Reference for Measuring Screens
- Command Reference for MS Information
- Command Reference for Peak TX Power /Burst Timing/Power Ramp Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Spectrum Monitor Measurement Screen
- Command Reference for Stand-by Screens
- TRIGger Subsystem
- 4 Programming Command Cross Reference
- 5 Example Programs
- A Syntax Diagram
- B Command Difference between E6392A & E6392B
- Index

Chapter 3 73
Programming Command Reference
TESTs Subsystem for AUTOMATIC TEST
3. Programming Command
Reference
TESTs:AUTO:RESults:RAMP6:ZOOM ON|OFF|1|0
TESTs:AUTO:RESults:RAMP6:ZOOM?
This command activates the zooming function of the Power Ramp graph for each
of the six measurements. The choices are ON (1) and OFF (0). If set to ON, the
rising and trailing edges are expanded. At preset, these are set to OFF.
Power Ramp Marker Measurement
TESTs:AUTO:RESults:RAMP1:MARKer?
TESTs:AUTO:RESults:RAMP2:MARKer?
TESTs:AUTO:RESults:RAMP3:MARKer?
TESTs:AUTO:RESults:RAMP4:MARKer?
TESTs:AUTO:RESults:RAMP5:MARKer?
TESTs:AUTO:RESults:RAMP6:MARKer?
This query command returns a set of marker position values, <string 1>,
<string 2>, <string 3> and <string 4>, in the Power Ramp graph for
each of the six measurements.
• <string 1> (1 digit) is 0 when all values are within the normal range, or 1 if any
measurement is overranged, underranged or not made.
• <string 2> (1 digit) is the binary data, 0 or 1, for the pass (0) or fail (1) result.
• <string 3> (7 digits) is the marker position ranging from −009.25 to +156.25
(bits).
• <string 4> (5 digits) is the power level of the marker position ranging from
−99.9 to +99.9 (dB). If any measurement is overranged, underranged or not
made, the value −99.9 is returned.
Power Ramp Marker Position Control
TESTs:AUTO:RESults:RAMP1:MARKer:POINt UP|DOWN
TESTs:AUTO:RESults:RAMP1:MARKer:POINt <real>
TESTs:AUTO:RESults:RAMP1:MARKer:POINt?
TESTs:AUTO:RESults:RAMP2:MARKer:POINt UP|DOWN
TESTs:AUTO:RESults:RAMP2:MARKer:POINt <real>
TESTs:AUTO:RESults:RAMP2:MARKer:POINt?
TESTs:AUTO:RESults:RAMP3:MARKer:POINt UP|DOWN
TESTs:AUTO:RESults:RAMP3:MARKer:POINt <real>
TESTs:AUTO:RESults:RAMP3:MARKer:POINt?
TESTs:AUTO:RESults:RAMP4:MARKer:POINt UP|DOWN
TESTs:AUTO:RESults:RAMP4:MARKer:POINt <real>
TESTs:AUTO:RESults:RAMP4:MARKer:POINt?
TESTs:AUTO:RESults:RAMP5:MARKer:POINt UP|DOWN
TESTs:AUTO:RESults:RAMP5:MARKer:POINt <real>
TESTs:AUTO:RESults:RAMP5:MARKer:POINt?