Specifications
Table Of Contents
- E6392-90042.pdf
- E6392-90042_manual
- Front Matter
- Contents
- 1 Preparing for Use
- 2 Programming Command Guidelines
- 3 Programming Command Reference
- IEEE Common Command
- CONFigure Subsystem
- DISPlay Subsystem
- HCOPy Subsystem
- RFGenerator Subsystem
- SMONitor Subsystem
- SYSTem Subsystem
- TESTs Subsystem for AUTOMATIC TEST
- All Tests Results
- All Tests Results
- Command Reference for Burst Timing/Power Ramp Measurement Screen
- Command Reference for DC Current Measurement Screen
- Command Reference for MS Information
- Command Reference for Peak TX Power Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Stand-by/Measuring Screens
- TESTs Subsystem for MANUAL TEST
- Command Reference for DC Current Measurement Screen
- Command Reference for Measuring Screens
- Command Reference for MS Information
- Command Reference for Peak TX Power /Burst Timing/Power Ramp Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Spectrum Monitor Measurement Screen
- Command Reference for Stand-by Screens
- TRIGger Subsystem
- 4 Programming Command Cross Reference
- 5 Example Programs
- A Syntax Diagram
- B Command Difference between E6392A & E6392B
- Index

58 Chapter 3
Programming Command Reference
DISPlay Subsystem
Peak TX Power/Burst Timing/Power Ramp
DISPlay:MANual:TPOWer
This command selects the Peak TX Power/Burst Timing/Power Ramp measuring
screen for MANUAL TEST.
NOTE If Option 040 is installed and the mode is set to GPRS in
MANUAL TEST, this command selects the Peak TX Power/Power
vs Time screen.
Phase Error/Frequency Error
DISPlay:MANual:PHASe
This command selects the Phase Error/Frequency Error measuring screen for
MANUAL TEST.
Sensitivity/RX Quality/RX Level
DISPlay:MANual:SENSitivity
This command selects the Sensitivity/RX Quality/RX Level measuring screen for
MANUAL TEST.
NOTE If Option 002 is installed and the mode is set to ASYNC in
MANUAL TEST, this command is invalid.
If Option 040 is installed and the mode is set to GPRS in
MANUAL TEST, this command selects the Sensitivity screen to
measure BLER.
Spectrum Monitor
DISPlay:MANual:SMONitor
This command selects the Spectrum Monitor measuring screen for MANUAL
TEST.
Stand-by
DISPlay:MANual:STBY
This command selects the Stand-by screen for MANUAL TEST.
NOTE This command is valid only for Test Sets without any of Option 002
and Option 040.
Stand-by (Asynchronous Mode)
DISPlay:MANual:ASYN:STBY
This command selects the asynchronous mode Stand-by screen for MANUAL
TEST.