Specifications
Table Of Contents
- E6392-90042.pdf
- E6392-90042_manual
- Front Matter
- Contents
- 1 Preparing for Use
- 2 Programming Command Guidelines
- 3 Programming Command Reference
- IEEE Common Command
- CONFigure Subsystem
- DISPlay Subsystem
- HCOPy Subsystem
- RFGenerator Subsystem
- SMONitor Subsystem
- SYSTem Subsystem
- TESTs Subsystem for AUTOMATIC TEST
- All Tests Results
- All Tests Results
- Command Reference for Burst Timing/Power Ramp Measurement Screen
- Command Reference for DC Current Measurement Screen
- Command Reference for MS Information
- Command Reference for Peak TX Power Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Stand-by/Measuring Screens
- TESTs Subsystem for MANUAL TEST
- Command Reference for DC Current Measurement Screen
- Command Reference for Measuring Screens
- Command Reference for MS Information
- Command Reference for Peak TX Power /Burst Timing/Power Ramp Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Spectrum Monitor Measurement Screen
- Command Reference for Stand-by Screens
- TRIGger Subsystem
- 4 Programming Command Cross Reference
- 5 Example Programs
- A Syntax Diagram
- B Command Difference between E6392A & E6392B
- Index

44 Chapter 3
Programming Command Reference
CONFigure Subsystem
This command sets a value of Power Control Level (PWR CNTL) to each of the
High, Medium, and Low ranges for AUTOMATIC TEST, or sets a value of PWR
CNTL for MANUAL TEST, for each radio standard set by the Radio Format
command. The allowable range and preset values are as follows:
Radio Standard
CONFigure:CONDition:RFORmat
GSM900|E-GSM|DCS1800|PCS1900
CONFigure:CONDition:RFORmat?
This command defines a system of Radio Standard to be tested. The choices are
GSM900, E-GSM, DCS1800, and PCS1900. At preset, this is set to GSM900.
RF Output
CONFigure:CONDition:RFOUtput AUTO|ON
CONFigure:CONDition:RFOUtput?
This command defines a mode of RF Output. The choices are AUTO and ON. If
set to AUTO, the RF signal is supplied only during test cycles. At preset, this is set
to ON.
RX Level Limit
CONFigure:CONDition:LIMit:LEVel <int l>,<int h>
CONFigure:CONDition:LIMit:LEVel?
This command specifies the low and high limits for RX Level tests, for each radio
standard set by the Radio Format command. The choices and the preset values are
as follows:
RFORmat Allowable Range
Preset Value
AUTO MANUAL
GSM900 2 (+39 dBm) to 19 (+5 dBm) 5, 10, 15 5
E-GSM 2 (+39 dBm) to 19 (+5 dBm) 5, 10, 15 5
DCS1800 0 (+30 dBm) to 15 (+0 dBm), or
29 (+36 dBm) to 31 (+32 dBm)
0, 5, 10 0
PCS1900 0 (+30 dBm) to 15 (+0 dBm), or
30 (+33 dBm) to 31 (+32 dBm)
0, 5, 10 0