Specifications

Table Of Contents
Chapter 3 41
Programming Command Reference
CONFigure Subsystem
3. Programming Command
Reference
NOTE If Option 040 is installed and the mode is set to GPRS, BER can
noe is measured in MANUAL TEST.
BLER Limit
CONFigure:CONDition:LIMit:BLER <real h> [PCT]
CONFigure:CONDition:LIMit:BLER?
This command specifies the high limit for BLER (block error ratio) tests if Option
040 is installed and the GPRS mode is selected. The allowable range is from 0.00
to 99.99 (%) in 0.01 steps. At preset, this is set to 2.44 (%).
NOTE If the mode is set to GPRS on the Test Set with Option 040,
Sensitivity in BLER is measured in MANUAL TEST.
BS Level
CONFigure:CONDition:AMPLitude <real> [DBM]
CONFigure:CONDition:AMPLitude?
This command specifies an amplitude of the Test Set applied to the mobile under
test. The allowable range is from 110.0 to 50.0 (dBm) in 0.5 steps. At preset,
this is set to 50.0 (dBm).
Burst Timing Limit
CONFigure:CONDition:LIMit:BTIMing
<real l>,<real h> [Bits]
CONFigure:CONDition:LIMit:BTIMing?
This command specifies the low and high limits for Burst Timing tests. The
allowable range is from 9.9 to +9.9 (bits) in 0.1 steps. At preset, these are set to
1.0 and +1.0 (bits).
DC Current Limit
CONFigure:CONDition:LIMit:CURRent:CAMP
<int l>,<int h> [MA]
CONFigure:CONDition:LIMit:CURRent:CAMP?
CONFigure:CONDition:LIMit:CURRent:TALK
<int l>,<int h> [MA]
CONFigure:CONDition:LIMit:CURRent:TALK?
This command specifies the low and high limits for DC Current tests at Camp On
or Talk. The allowable range is from 3 to 1000 (mA) in 1 steps. At preset, these are
set to 50 and 200 (mA) for Camp On, and 300 and 700 (mA) for Talk, respectively.
NOTE If Option 002 is installed and the mode is set to ASYNC in
MANUAL TEST, the limits for Talk are used for DC Current tests.
If Option 040 is installed and the mode is set to GPRS in
MANUAL TEST, the limits for Talk are used for DC Current tests.