Specifications
Table Of Contents
- E6392-90042.pdf
- E6392-90042_manual
- Front Matter
- Contents
- 1 Preparing for Use
- 2 Programming Command Guidelines
- 3 Programming Command Reference
- IEEE Common Command
- CONFigure Subsystem
- DISPlay Subsystem
- HCOPy Subsystem
- RFGenerator Subsystem
- SMONitor Subsystem
- SYSTem Subsystem
- TESTs Subsystem for AUTOMATIC TEST
- All Tests Results
- All Tests Results
- Command Reference for Burst Timing/Power Ramp Measurement Screen
- Command Reference for DC Current Measurement Screen
- Command Reference for MS Information
- Command Reference for Peak TX Power Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Stand-by/Measuring Screens
- TESTs Subsystem for MANUAL TEST
- Command Reference for DC Current Measurement Screen
- Command Reference for Measuring Screens
- Command Reference for MS Information
- Command Reference for Peak TX Power /Burst Timing/Power Ramp Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Spectrum Monitor Measurement Screen
- Command Reference for Stand-by Screens
- TRIGger Subsystem
- 4 Programming Command Cross Reference
- 5 Example Programs
- A Syntax Diagram
- B Command Difference between E6392A & E6392B
- Index

38 Chapter 3
Programming Command Reference
CONFigure Subsystem
If set to LOCK, only AUTOMATIC TEST and CONFIGURATION are allowed to
change settings. In AUTOMATIC TEST, however, Radio Standard, BCCH, TCH
(TALK), Multi Band, DC Power, and Variable are locked and cannot be changed.
This command is not identical to Lock System Panel of the System commands.
See “Lock System Panel” on page 68.
Printer Control
CONFigure:PRINter HPPCL|ESCP
CONFigure:PRINter?
This command toggles the printer type between HPPCL and ESCP. At preset, this
is set to HPPCL.
Time
CONFigure:TIME <int h>,<int m>
CONFigure:TIME?
This command sets the clock of the Test Set. <int h> is the hour from 00 to 23 and
<int m> is the minutes from 00 to 59.
Command Reference for File Management Screen
The File commands are used to manage the test setup files on an SRAM memory
card.
Send the "DISPlay:CONFigure:FILE" command to display the File Management
screen before sending the following commands.
Delete File
CONFigure:FILE:DELete <string>
This command deletes the test setup file specified by <string> (file name) from an
SRAM memory card. <string> must be an existing file name on the SRAM
memory card. There is no query form of this command.
Format Card
CONFigure:FILE:FORMat
This command initializes an SRAM memory card, however, the firmware update
cards can not be initialized. There is no query form of this command.
List Files
CONFigure:FILE:LIST?
This query command returns a list of all setup files in an SRAM memory card. The
output format is <string total>, <string filenumber_1>, <string filename_1>,
<string date_1>, <string time_1>, <string comment_1>, ... , <string
filenumber_n>, <string filename_n>, <string date_n>, <string time_n>, and
<string commnet_n>.