Specifications
Table Of Contents
- E6392-90042.pdf
- E6392-90042_manual
- Front Matter
- Contents
- 1 Preparing for Use
- 2 Programming Command Guidelines
- 3 Programming Command Reference
- IEEE Common Command
- CONFigure Subsystem
- DISPlay Subsystem
- HCOPy Subsystem
- RFGenerator Subsystem
- SMONitor Subsystem
- SYSTem Subsystem
- TESTs Subsystem for AUTOMATIC TEST
- All Tests Results
- All Tests Results
- Command Reference for Burst Timing/Power Ramp Measurement Screen
- Command Reference for DC Current Measurement Screen
- Command Reference for MS Information
- Command Reference for Peak TX Power Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Stand-by/Measuring Screens
- TESTs Subsystem for MANUAL TEST
- Command Reference for DC Current Measurement Screen
- Command Reference for Measuring Screens
- Command Reference for MS Information
- Command Reference for Peak TX Power /Burst Timing/Power Ramp Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Spectrum Monitor Measurement Screen
- Command Reference for Stand-by Screens
- TRIGger Subsystem
- 4 Programming Command Cross Reference
- 5 Example Programs
- A Syntax Diagram
- B Command Difference between E6392A & E6392B
- Index

160 Chapter 5
Example Programs
AUTOMATIC TEST Sample Program
1690 REPEAT
1700 OUTPUT Serial_port;"TEST:AUTO:MEAS:SIGN:STAT?"
1710 ENTER Serial_port;S
1720 UNTIL BIT(S,4)=1
1730 !
1740 !***** MS Release
1750 !
1760 DISP "Execute MS Release. Press CONTINUE."
1770 PAUSE
1780 !
1790 !***** BS Call and BS Release
1800 !
1810 DISP "Answer the call. Press CONTINUE."
1820 PAUSE
1830 DISP
1840 !
1850 REPEAT
1860 OUTPUT Serial_port;"TEST:AUTO:MEAS:SIGN:STAT?"
1870 ENTER Serial_port;S
1880 UNTIL BIT(S,7)=1
1890 DISP "Measurement ends."
1900 !
1910 !***** Results Display
1920 !
1930 OUTPUT Serial_port;"TEST:AUTO:RES:ALL?"
1940 ENTER Serial_port;A,B
1950 IF A=0 THEN
1960 PRINT "All Sequences are Passed."
1970 ELSE
1980 IF BIT(A,0)=1 THEN PRINT "LOC.Update failed."
1990 IF BIT(A,1)=1 THEN PRINT "MS Call failed."
2000 IF BIT(A,2)=1 THEN PRINT "Talk failed."
2010 IF BIT(A,3)=1 THEN PRINT "RF Test failed."
2020 IF BIT(A,4)=1 THEN PRINT "MS Release failed."
2030 IF BIT(A,5)=1 THEN PRINT "BS Call failed."
2040 IF BIT(A,6)=1 THEN PRINT "BS Release failed."
2050 END IF
2060 !
2070 IF B<>0 THEN